![Gema OptiGun GA03-E Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/gema/optigun-ga03-e/optigun-ga03-e_operating-instructions-and-spare-parts-list_2206658026.webp)
V 02/22
24
•
Cleaning and maintenance
OptiGun GA03-E
3.
Remove the spray nozzle from the gun and clean it with compressed
air
4.
Blow through the gun with compressed air, beginning from the con-
nection in flow direction
5.
Clean the integrated gun tube with the brush supplied, if necessary
6.
Blow through the gun with compressed air again
7.
Clean the powder hose
8.
Reassemble the gun and connect it
Cleaning the spray nozzle
Daily or after each shift
–
Clean the inside and outside of the spray nozzle with compressed
air.
Never immerse the parts in solvents!
–
Check the seating of the spray nozzles.
ATTENTION
Threaded sleeve not tightened well
If the spray nozzle is just fitted loosely, there is danger of a flash-
over of the gun high voltage, which can damage the gun!
► Always tighten the threaded sleeve well!
1.
Weekly
–
Remove the spray nozzle and clean on the inside with compressed
air. If sinterings should have formed, then they have to be removed!
Monthly
–
Check spray nozzle for wear
The flat jet nozzle is to be replaced, if:
–
the spray pattern is no longer a regular oval
–
deeper grooves are in the nozzle slot, or even the wall thickness is
no longer recognizable
–
the wedge of the electrode holder is worn
Nozzles with deflectors:
–
if the wedge of the electrode holder is worn down, then the electrode
holder is to be replaced