OptiFeed BigBag (FPS16)
Start-up
•
31
Parameters
Block No.
(Parameter)
Description
Default value
Remarks
B001
Powder flow
measurement delay
2.0 sec.
B002
Cylinder lift/lower cycle
Lift:
TH = 30.0 secs.
Lowering:
TL = 50.0 secs.
B009
Analog threshold values
of the pump 1 switch
Threshold value down:
ON = 150
Threshold above:
OFF = 900
1024 digits corresponds
to 2.5 bar (e.g. 150 =
0.36 bar)
B010
Analog threshold values
of the pump 2 switch
Threshold value down:
ON = 250
Threshold above:
OFF = 900
1024 digits corresponds
to 2.5 bar (e.g. 150 =
0.36 bar)
B014
Error message delay
T = 50.0 secs.
B016
Debouncing of B001
T = 10.0 secs.
The pressure
monitoring must
indicate
no powder
for
a defined duration, until
the signal will be
evaluated
B017
Debouncing of B014
T = 3.0 secs.
The
no powder
signal
must be present for a
defined duration
For the adjustment and the operation of the powder transport,
the corresponding powder pump documentation must be
observed!
Powder flow detection
Overview
If craters form through the suction procedure in the powder container, the
powder flow can thereby be influenced negatively. In order to prevent this,
a pressure sensor measures the backpressure in the powder hose.
If the pressure decreases under a defined threshold value, the powder
container is lowered to the floor and lifted again, so that the craters can
be loosen.
Содержание FPS16
Страница 6: ......
Страница 34: ...Rev 00 03 22 34 Start up OptiFeed BigBag FPS16 ...
Страница 38: ...Rev 00 03 22 38 Operation OptiFeed BigBag FPS16 ...
Страница 52: ...Rev 00 03 22 52 Fault clearance OptiFeed BigBag FPS16 ...
Страница 54: ...Rev 00 03 22 54 Disposal OptiFeed BigBag FPS16 ...
Страница 60: ......
Страница 62: ...Rev 00 ...