Preparing the powder box
1.
Lift the fluidizing/suction unit
2.
Hook in the large container with all four loops
3.
Open the top of the container opening to insert the
fluidization/suction unit
4.
Fit the vibrating plate
5.
Place the fluidizing/suction unit onto the powder
Powder fluidizing
The fluidization of the coating powder with fluidizing air improves the
conveying characteristics of the powder. The fluidization and vibration
characteristics of the powder are dependent on the powder type, the air
humidity and the ambient temperature.
The fluidization and the vibration start by switching on the powder feed
(see also "Functional check").
Parameterization
The various time sequences can be easily set and adapted to all plant-
specific requirements by the aid of a simple menu control unit.
Read carefully this section, before access to a menu option!
Standard display
not to be used
Set parameter
not to be used
not to be used
Parameter input display
Block number
The value set at Parameter Time
ON
The value set at Parameter Time
OFF
Current time