Rev. 00 03/22
26
•
Start-up
OptiFeed BigBag (FPS16)
Main module inputs
Entry
Description
I1
External interlocking/
Automatic
operating mode must
be operated with switch
– control unit is ready for
operation. Powder box will be lifted
I2
External
fresh powder
requirement (pump 1)
I3
External
fresh powder
requirement (pump 2)
I4
Activate cleaning mode
I5
Reserve
I6
Reserve
I7
Analog input 0-10 V / pressure sensor for pump 1
I8
Analog input 0-10 V / pressure sensor for pump 2
Main module outputs
Output
Description
Q1
main solenoid valves
Q2
Solenoid valve
– lift cylinder
Q3
Warning lamp - no powder
Q4
Potential-free contact
– no powder
(max. voltage 230 VAC)
Additional module inputs
Entry
Description
I1-I4
Reserve
Additional module outputs
Output
Description
Q1
Conveying ON - pump 1
Q2
Conveying ON - pump 2
Q3
Pinch valve
– preventing excess air suction of pump 1
Q4
Pinch valve
– preventing excess air suction of pump 2