After filter pressure monitoring
MagicControl 4.0 (CM40)
Measuring point
In the ducting from the booth to the cyclone there is a pre-drilled
measuring point in newly delivered plants. This is located below the
elbow.
Fig. 97: Measuring point
Measuring procedure
1.
Run telescopic probe into the center of the tube
2.
Take one or more measurements lasting 60 seconds.
– Tests have shown that the measurement is most accurate if the
measurement is only made in the center of the pipe.
3.
The results are displayed in the Smart Probes app.