www.gemu-group.com
17 / 24
GEMÜ 225
14 Troubleshooting
Error
Error cause
Troubleshooting
No function
No power supply
Check power supply and connection with
product label
Solenoid coil faulty
Replace solenoid valve
Plug wrongly connected
Check connection of plug and correct if
necessary
Operating pressure too high
Check operating pressure, reduce if ne-
cessary
PTFE bush leaking
Replace solenoid valve
Armature blocked
Replace solenoid valve
Solenoid valve leaking
Valve seat leaking
Replace solenoid valve
Solenoid valve does not close
Manual override engaged/actuated
Check the position of the manual over-
ride and close if necessary