These operating instructions belong exclusively to this product.
It contains important information on commissioning and
handling. Pay attention to this, even if you pass this product on
to third parties. You should therefore archive these operating
instructions for future reference.
1. introduction
Dear customer, thank you for purchasing this product. You have
acquired a product that has been built according to the state
of the art.
In order to maintain this status and to ensure safe operation,
you as the user must observe these operating instructions!
2. safety instructions
In the event of damage caused by non-observance of these
operating instructions, the guarantee expires!
For further damages we do not accept liability!
We assume no liability for property damage or personal injury
caused by improper handling or failure to observe the safety
instructions. In such cases, any guarantee claim will expire.
For safety reasons, unauthorized modifications and / or chan-
ges to the product are not permitted. Pay attention to a proper
commissioning. Please refer to these operating instructions.
3. Intended Use
The brew group thermometer shows the brewing temperature
shortly before the coffee puck. The brew group thermometer is
only for use in E61 brew groups with M6 inspection screw.
The thermometer must not be submerged in water.
4. Installation
CAUTION:
The tip of the screw connection is very sensitive!
1.
Make sure that the coffee / espresso machine has cooled
down.
Caution, risk of burns!
2.
With the machine turned off, flush your group head to
relieve the pressure.
3.
Loosen the M6 screw with the tool provi-
ded for this purpose (not included), plea-
se make sure that you also remove the seal.
4.
Carefully remove the thermometer from the packaging.
5.
Make sure that the sealing ring is on the screw connec-
tion.
6.
Carefully screw the thermometer into the M6 thread of
the machine. Take a 10 mm open-ended wrench (not in-
cluded) and tighten the screw connection. (max. 0,9 Nm)
7.
Use the supplied Allen key to loosen the small screw
(approx. 1/2 turn) until you can easily turn the thermo-
meter.
8.
Align the thermometer
9.
Tighten the small screw again slightly.
10.
Check the tightness by pressing the
Rinse the grouphead with a blind basket.
Instruction manual - ENGLISH-
GBTVAT-01
Group head thermometer for E61 brew groups