The drive is measured during automatic commissioning in the "normal" positions in such a way that the average
kinetic energy is ≤
10 J
. The value is reduced by 16% for the glass doors. See "Settings with HEX switch S2".
5.4. Manually with the service program
Service program: The service programs are software programs for the KFM LD drive.
If a PC or laptop is connected to the controller of the drive, the door drive can be set and individually adjusted
in a menu-driven manner with the help of the service program. This program can also be used to read out the
error stack in the controller memory.
This program are used:
• E@syDrives
This service programs is necessary for entering, monitoring and changing set values. A description of the pro-
gram and the required input parameters can be obtained from SIEI-AREG GmbH.
In certain cases, it is necessary to adjust or change the basic set values with a service program.
5.5. Meaning of the LED indicator
Note !
Further information on this topic can also be found in the Easy-drives help system.
Fig. 22
H1
green
H2
yellow
H3
green
H4
red
Meaning
*
*
-*
HEX switch S2 in position D, E or F. Press and hold button T1 for 10 seconds.
After releasing, the aipm learning program starts up.
*
*
-*
Close the fast door panel by exactly 250 mm, then press button T1.
0
0
0
-*
Approx. 5 seconds after releasing the button. The learned value is stored.
After successful learning, a RESET takes place automatically.
Tab. 26 Process for learning gear ratios - aipm