GQ 15 / 25 / 50 / 90 A
SINGLE PHASE SOLID STATE RELAYS
Main features
• Alternating current solid state relay
• Zero crossing switching
• Copper/semiconductor coupling
technology
• 15, 25, 50 and 90Arms nominal
current
• Non-repetitive voltage: up to
1600Vp
• Nominal Voltage: up to 600 Vac
• Control voltage : 3...32Vcc and
20...260Vac/Vcc with connector
• Isolation ((input-output)
4000Vrms
• Red LED drive active signal
• Internal MOV (option)
Main applications
• Packaging Machinery
• Thermoforming
• Plastic extrusion lines
• Industrial ovens and
furnaces
• Control application with
high switching speed
PROFILE
Zero crossing relay with antiparallel thy-
ristor output is the most used solid state
relay in industrial applications.
In fact, it can be used for resistive, inducti-
ve and capacity loads.
“Zero crossing” relay is energised when
voltage meets the zero point and disener-
gised when current meets the zero point,
depending on the signal control on the
input circuit.
This relay has been designed to stand
high-value transitory applications .
When the relay has to stand high currents
for a long period, it is necessary to grant a
proper dissipation and an adequate elec-
trical connection between relay terminals
and the load.
Varistors, fuses, thermostats and fans are
available as fittings.
Use the relay with an opportune heatsink
(see section accessories).
TECHNICAL DATA
General features
Rated frequency: 45...65Hz
Activation time:
GQ...-D- ≤1/2 cicle GQ...-A- ≤1 cicle
Deactivation time:
GQ...-D- ≤1/2 cicle GQ...-A- ≤1 cicle
Power factor: ≥0,5
Protection level: IP20
• Uimp = 4,8KV
• Ui
= 660V
• Overload current profile = 10
• Conditional short circuit current = 5KA with
type 1 coordination and respective fuse protec-
tions.
GQ15/25 fuse type aM6A
GQ50 fuse type aM16A
GQ90 fuse type aM20A
GQ...- 24-
Nominal voltage: 24...230 Vac
(max range 20...253Vac)
Non-repetitive voltage: ≥ 600 Vp
Zero switching voltage: ≤ 20V
GQ...- 48-
Nominal voltage: 48...480 Vac
(max range 40...528Vac)
Non-repetitive voltage: ≥ 1200 Vp
Zero switching voltage: ≤ 40 V
GQ...- 60-
Nominal voltage: 48...600 Vac
(max range 40...660Vac)
Non-repetitive voltage: ≥ 1200 Vp
Zero switching voltage: ≤ 40V
Control input A1 - A2
GQ...-D-
Control voltage: 3...32Vcc
Turn ON voltage: ≥ 2,7Vc.c
Turn OFF voltage: ≤ 1Vcc
Reverse voltage: < 36Vcc
Consumption: ≤ 13mA@32V
GQ...-A-
Control voltage: 20...260Vac/Vcc
Turn ON voltage: ≥ 15Vac/Vcc
Turn OFF voltage: ≤ 6Vac/Vcc
Consumption: ≤ 8mAac/cc@260Vac/Vcc
Series connection of control inputs:
max. no. GQ...-A in series = Vcontrol
-10% / 20
Output L1 - T1
GQ - 15 -
Nominal current :
AC51: 15Arms; AC53A (*): 3Arms
Min load current: 0,1Arms
Repetitive overcurrent t=1 s: ≤ 35Arms
Non-repetitive overcurrent t=20ms:200Ap