
ADV200 WA • Functions description and parameters list
33
When set to
None
, no setting is executed.
Input = 0
sets input = 0 i.e. a temporary reference setting is performed and the previous reference value is
maintained. The output of the Motor potentiometer function varies with the set ramp times. The previous refer-
ence value is restored when the preset command is removed.
Input = low lim
sets Inp = low lim i.e. a temporary reference setting is performed and the previous reference
value is maintained. The output of the Motor potentiometer function varies with the set ramp times. The previ-
ous reference value is restored when the preset command is removed.
Input & ref = 0
sets Inp = 0 and Ref = 0 i.e. a definitive reference setting is performed. The output of the Mo-
tor potentiometer function varies with the set ramp times.
Input & ref = low lim
sets Inp = low lim and Ref = low lim i.e. a definitive reference setting is performed. The
output of the Motor potentiometer function varies with the set ramp times.
Output = 0
sets Out = 0 i.e. a temporary output setting for the Motor potentiometer function is performed. The
previous reference value is maintained. If the preset command is enabled, the output of the Motor potentiom-
eter function continues to be = 0, if the preset command is not enabled the output of the Motor potentiometer
function varies with the set ramp times.
Output = low lim
sets Out = low lim i.e. a temporary setting for the output of the Motor potentiometer function
is performed..The previous reference value is maintained. If the preset command is enabled, the output of the
Motor potentiometer function continues to be = low lim, if the preset command is not enabled the output of the
Motor potentiometer function varies with the set ramp times.
Output & ref = 0
sets Out = 0 i.e. a definitive setting for the output of the Motor potentiometer function is
performed.
Output & ref = low
lim sets Out = low lim i.e. a definitive setting for the output of the Motor potentiometer
function is performed.
Input = upp lim
sets Inp = upp lim i.e. a temporary setting for the reference is performed and the previous
reference value is maintained. The output of the Motor potentiometer function varies with the set ramp times.
The previous reference value is restored when the preset command is removed.
Input & ref = upp lim
sets Inp = upp lim and Ref = upp lim i.e. a definitive reference setting is performed. The
output of the Motor potentiometer function varies with the set ramp times.
When
Freeze input
is set, the Up and Down commands are temporarily disabled.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
8.8
884 Mpot up src
LINK 16
6000
0
16384
RW VS
Selection of the origin (source) of the signal that increases the speed reference of the motor potentiometer
with the set ramp. The terminal to be associated with this function can be selected from the “
L_DIGSEL2
”
selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
8.9
886 Mpot down src
LINK 16
6000
0
16384
RW VS
Selection of the origin (source) of the signal that decreases the speed reference of the motor potentiometer
with the set ramp. The terminal to be associated with this function can be selected from the “
L_DIGSEL2
”
selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
8.10
888 Mpot invert src
LINK 16
6000
0
16384
ERW VS
Selection of the origin (source) of the signal that inverts the speed reference of the motor potentiometer. The
terminal to be associated with this function can be selected from the “
L_DIGSEL2
” selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
8.11
890 Mpot preset src
LINK 16
6000
0
16384
ERW VS
Selection of the origin (source) of the signal to preset the motor potentiometer function. The signal to be as-
sociated with this function can be selected from the “
L_DIGSEL2
” selection list.
Содержание ADV200 WA
Страница 84: ...84 ADV200 WA Functions description and parameters list 22 3 FUNCTIONS DC BRAKING ...
Страница 274: ...274 ADV200 WA Block Diagrams G Block Diagrams System Diagrams Index Drive overview ...
Страница 275: ...ADV200 WA Block Diagrams 275 References ...
Страница 276: ...276 ADV200 WA Block Diagrams Ramps Multireference ...
Страница 277: ...ADV200 WA Block Diagrams 277 Motorpotentiometer Jog function ...
Страница 278: ...278 ADV200 WA Block Diagrams Monitor function ...
Страница 279: ...ADV200 WA Block Diagrams 279 ...
Страница 280: ...280 ADV200 WA Block Diagrams Commands ...
Страница 281: ...ADV200 WA Block Diagrams 281 ...
Страница 282: ...282 ADV200 WA Block Diagrams Digital inputs ...
Страница 283: ...ADV200 WA Block Diagrams 283 Digital outputs ...
Страница 284: ...284 ADV200 WA Block Diagrams Analog inputs ...
Страница 285: ...ADV200 WA Block Diagrams 285 ...
Страница 286: ...286 ADV200 WA Block Diagrams Analog outputs ...
Страница 287: ...ADV200 WA Block Diagrams 287 Speed reg gains ...
Страница 288: ...288 ADV200 WA Block Diagrams VF parameters ...
Страница 289: ...ADV200 WA Block Diagrams 289 Functions ...
Страница 290: ...290 ADV200 WA Block Diagrams ...
Страница 291: ...ADV200 WA Block Diagrams 291 ...
Страница 292: ...292 ADV200 WA Block Diagrams ...
Страница 293: ...ADV200 WA Block Diagrams 293 Process ...
Страница 294: ...294 ADV200 WA Block Diagrams ...
Страница 295: ...ADV200 WA Block Diagrams 295 ...
Страница 296: ...296 ADV200 WA Block Diagrams ...
Страница 297: ...ADV200 WA Block Diagrams 297 ...
Страница 298: ...298 ADV200 WA Block Diagrams ...
Страница 299: ......