ADV200 WA • Troubleshooting
271
Index Error message shown
on the display
Sub-code
Description
Solution:
If the message appears with a value other than 0, follow the instructions supplied for each particular case
and repeat
Autotune
. This should be performed using the wizard function available from the keypad (STARTUP WIZ-
ARD) and the Tool software on the PC.
Pay attention to all motor plate data parmaeters, especially:
-
Rated speed
,
Motor rated speed
in rpm.
-
Rated frequency
,
Motor rated frequency
in Hz
-
Pole pairs
,
Motor pole pairs
Take care not to set the
Rated speed
parameter to the synchronous speed. The value of the
Rated speed
parameter
must be less than: [(
Rated frequency
* 60) /
Pole pairs
].
If the problem persists even after following the instructions supplied, confirm the values of the motor plate data param-
eters, execute the
Take parameters
command but not
Autotune
.
6
Power config
Condition:
may occur during recognition of power cards. If this message is displayed, it is not possible to drive the
motor.
0020H-32
The power card is configured for a drive that is incompatible with the regulation card
0021H-33
The configuration of the power card is not compatible with the regulation card
0017H-23
The configuration required is not available on the power card
Solution:
Download the correct configuration on the power card
7
Save par failed
Condition:
during transfer of the parameters from the drive to the memory of the keypad
0H-0
Communication error
0025H-37
The data saved on the keypad are not valid
0026H-38
Incompatible drive series
0027H-39
Incompatible software version
0028H-40
Incompatible drive size
0029H-41
Error during saving of parameters on the drive
Solution:
8
Load par failed
Condition:
during transfer of the parameters from the memory of the keypad to the drive
9
Load par incomplete
0H-0
Communication error
0025H-37
The data saved on the keypad are not valid.
No parameter is transferred from the keypad to the drive
0026H-38
Incompatible drive series.
No parameter is transferred from the keypad to the drive
0027H-39
Incompatible software version.
All the parameters present in the memory of the keypad have been transferred to the drive. The
set of parameters transferred refers to a drive with a different firmware version; therefore, certain
parameters may not be updated.
0028H-40
Incompatible drive size.
All the parameters present in the memory of the keypad (excluding those that depend on the size
of the drive), have been transferred to the drive. The parameters that depend on size maintain
their original value.
0029H-41
Error during saving of parameters on the drive.
All the parameters present in the memory of the keypad have been transferred to the drive. The
transfer of one or more parameters has caused an “out of range” error, or one or more parameters
does not exist. At the end of transfer, one or more parameters may not have been updated.
002AH-42
PLC application release and version not compatible.
All parameters in the keypad memory have been transferred to the drive.
The transferred set of parameters relates to a drive with a PLC application in which the version
and release of the application are different. As a result some of the PLC application parameters
may not be updated.
002BH-43
PLC application not compatible.
All the parameters in the keypad memory except those relating to the PLC applciation have been
transferred to the drive.
The transferred set of parameters relates to a drive with a different PLC application. As a result
none of the PLC application parameters are updated.
Solution:
Recover a set of parameters from a compatible drive (model and size)
10
Options config error Condition:
may occur at drive start-up, during recognition of the optional cards installed
0001H-1
Non-permissible optional card in slot 1
0002H-2
Non-permissible optional card in slot 2
0004H-4
Non-permissible optional card in slot 3
0010H-16
Conflict slot 1 with slot 2
0020H-32
Conflict slot 1 with slot 3
0040H-64
Conflict slot 2 with slot 3
Содержание ADV200 WA
Страница 84: ...84 ADV200 WA Functions description and parameters list 22 3 FUNCTIONS DC BRAKING ...
Страница 274: ...274 ADV200 WA Block Diagrams G Block Diagrams System Diagrams Index Drive overview ...
Страница 275: ...ADV200 WA Block Diagrams 275 References ...
Страница 276: ...276 ADV200 WA Block Diagrams Ramps Multireference ...
Страница 277: ...ADV200 WA Block Diagrams 277 Motorpotentiometer Jog function ...
Страница 278: ...278 ADV200 WA Block Diagrams Monitor function ...
Страница 279: ...ADV200 WA Block Diagrams 279 ...
Страница 280: ...280 ADV200 WA Block Diagrams Commands ...
Страница 281: ...ADV200 WA Block Diagrams 281 ...
Страница 282: ...282 ADV200 WA Block Diagrams Digital inputs ...
Страница 283: ...ADV200 WA Block Diagrams 283 Digital outputs ...
Страница 284: ...284 ADV200 WA Block Diagrams Analog inputs ...
Страница 285: ...ADV200 WA Block Diagrams 285 ...
Страница 286: ...286 ADV200 WA Block Diagrams Analog outputs ...
Страница 287: ...ADV200 WA Block Diagrams 287 Speed reg gains ...
Страница 288: ...288 ADV200 WA Block Diagrams VF parameters ...
Страница 289: ...ADV200 WA Block Diagrams 289 Functions ...
Страница 290: ...290 ADV200 WA Block Diagrams ...
Страница 291: ...ADV200 WA Block Diagrams 291 ...
Страница 292: ...292 ADV200 WA Block Diagrams ...
Страница 293: ...ADV200 WA Block Diagrams 293 Process ...
Страница 294: ...294 ADV200 WA Block Diagrams ...
Страница 295: ...ADV200 WA Block Diagrams 295 ...
Страница 296: ...296 ADV200 WA Block Diagrams ...
Страница 297: ...ADV200 WA Block Diagrams 297 ...
Страница 298: ...298 ADV200 WA Block Diagrams ...
Страница 299: ......