____________________ _
ADL300-EPCv2- User Guide
Page 16 of 64
3.3 LIFT CONTROL COMMANDS
The following commands are available:
•
Jog Forward
(
JogFwd
)
•
Jog Reverse
(
JogRev
)
•
Zero cycle
(
Cycle0
)
•
Self study
(
SelfStudy
)
•
Floor call
(
FloorCall
)
•
Forward
(
Forward
)
•
Reverse
(
Reverse
)
•
Stop
(
Stop
)
•
Maintenance
(
Maintenance
)
•
Realignment
(
Relevelling
)
•
Emergency command
(
Battery Run
)
•
Emergency function
(Battery Sel)
3.3.1 Maintenance command
The maintenance command acts on forward and reverse. For further details please see the description of the
two commands.
3.3.2 JogFwd command
The JogFwd command moves the lift car in the positive direction.
The following operating modes are implemented for this command:
•
On the rising edge of the JogFwd command the lift starts moving in the positive direction, which is
normally upwards. The following events may occur while the lift car is moving:
•
Removal of the JogFwd command: the lift stops in any point after completing the set deceleration
ramp.
WARNING!
As per specifications, the JogFwd command has no movement limits,
the user must therefore take care to
stop the lift in time.
3.3.3 JogRev command
The JogRev command moves the lift car in the negative direction.
The following operating modes are implemented for this command:
•
On the rising edge of the JogRev command the lift starts moving in the negative direction, which is
normally downwards. The following events may occur while the lift car is moving:
•
Removal of the JogRev command: the lift stops in any point after completing the set deceleration
ramp.
WARNING!
As per specifications, the JogRev command has no movement limits,
the user must therefore take care to
stop the lift in time.