163
13. ANNEXES
80703B_MHW_2850T/3850T_02-2019_ENG
13.1.4. Energy
Type
Group
Variable name
Interval
Use
Description
Boolean
Ret
System
ENERGY_RESET
R W Reset energy count.
Boolean
Ret
System
ENERGY_ENABLE
R W Enable energy counter command.
Register
Ret
System
ENERGY_TOTAL
R
Total energy counter
Register
Ret
System
DO_
n
_TON
R
Timer for ON status for digital output
n
.
n
can take on values from 1 to 48.
Register
Ret
System
DO_
n
_KWH
R
kWh distributed by digital output
n
.
n
can take on values from 1 to 48.
Register
Ret
System
PIDH_n_KWH
R
Total kWh for HEAT action of the PID controller.
n
can take on values from 1 to 16.
Register System
PIDC_n_KWH
R
Total kWh for COOL action of the PID controller.
n
can take on values from 1 to 16.
13.1.5. Weekly clock
Type
Group
Variable name
Interval
Use
Description
Boolean System ALARM_CLK
n
_CMD
m
R
Clock
n
command
m
.
n
can take on values from 1 to 4.
m
can take values 1 or 2.
Boolean System ALARM_CLK
n
_SET
R
Enable clock
n
(true = enabled).
n
can take on values from 1 to 4.
13.1.6. Alarms
Type
Group
Variable name
Interval
Use
Description
Boolean System ALARM_PRESENT
R
At least one alarm triggered.
Boolean System NEW_ALARM
R
No alarm triggered.
Boolean System PROBE_FAULT_
n
R
Probe
n
fault.
n
can take on values from 1 to 16.
Alarm
System NO_SD_CARD
R
SD card configured, but not present. Recording not
active.
Alarm
System DISK_FULL_NO_REC
R
Disc full, no new records will be made
Alarm
System IO_CABLE_FAULT
R
CANopen communication error
Alarm
System SIMULATOR_ON
R
Simulator active
Alarm
System DO_CC_M_N
R
Digital outputs in short circuit. The card number (1-
4) and output number (1-8) are indicated
Alarm
System FMIXn_AO_CC
R
Analogue outputs in short circuit or overloaded. The
number of the FMIX card involved is specified
Alarm
System FMIXn_AO_OP
R
Analogue outputs without load or with non-stan-
dard load. Typically indicates that wiring has been
hooked up on a given output. The number of the
FMIX card involved is specified
Alarm
System IO_GUARD_TIME
R
CANopen error
Alarm
System IO_COMM_ERROR
R
CANopen communication error
Alarm
System IO_WRONG_CARD_n
R
Error in a specific card
Alarm
System IO_WRONG_STATE
R
Generic card error; may, for example, indicate a
card change.
Alarm
System PID_n_RANGE_OUT
R
A number of PID variables have gone off the scale
(+32767, -32768 without considering decimal
points). Control not possible
Содержание 2850T
Страница 2: ......
Страница 6: ...80703B_MHW_2850T 3850T_02 2019_ENG 4...
Страница 10: ...80703B_MHW_2850T 3850T_02 2019_ENG 8...
Страница 20: ...80703B_MHW_2850T 3850T_02 2019_ENG 18...
Страница 34: ...80703B_MHW_2850T 3850T_02 2019_ENG 32...
Страница 104: ...80703B_MHW_2850T 3850T_02 2019_ENG 102...
Страница 106: ...80703B_MHW_2850T 3850T_02 2019_ENG 104...
Страница 124: ...80703B_MHW_2850T 3850T_02 2019_ENG 122...
Страница 128: ...80703B_MHW_2850T 3850T_02 2019_ENG 126...
Страница 156: ...80703B_MHW_2850T 3850T_02 2019_ENG 154...
Страница 162: ...80703B_MHW_2850T 3850T_02 2019_ENG 160...