Страница 1: ...UV C Air Sanitizers UVAIRO 600 SERVICE MANUAL ...

Страница 2: ...perations Safety 4 Maintenance Safety 5 OPERATIONS 6 System Overview 6 UV C Lamps 7 Air Infeed 7 Power Supply 7 CLEANING 8 Cleaning Notes 8 Lamp Cleaning 8 MAINTENANCE 9 Changing the Lamps 9 Changing the Air Filter 12 Changing the Power Supply Fuse 13 Service Parts List 14 Preventative Maintenance 14 ...

Страница 3: ...ile 231 773 8263 Muskegon MI 49442 Email sales geerpres com The information contained or disclosed by this document is considered proprietary by Geerpres This document items and information contained or disclosed herein shall not be used copied or reproduced in whole or in part nor shall the contents be revealed in any manner to any person unless written permission is obtained from Geerpres INTROD...

Страница 4: ...n the machine as well as their use Do not allow unauthorized personnel to operate or perform maintenance on this machine All personnel involved with the machine must be instructed in the following Safety procedures and accident prevention Specific safety procedures concerning the machine Locations and positions of the operating controls Personnel Safety Do not stick your hand arm or any other part...

Страница 5: ...oved from the machine area before resuming operations Do not leave maintenance tools wrenches screwdrivers etc inside the machine components or lying around the machine Power Supply Prior to performing maintenance or cleaning the machine unplug the machine to remove the electrical power source UV C Light Warnings WARNING When performing any servicing that requires the housings to be opened such as...

Страница 6: ...6 OPERATIONS System Overview Air Filter UVC Lamps UVairo 600 Air Sanitizer Overview Power Supply Fuse and On Off Switch ...

Страница 7: ... Life The lamps have a rated life of 9000 hours of operation 9000 hours is the point at which the actual output of UV C light may start to drop below 90 of the original and the risk of inadequate dosage exceeds allowable tolerances Air Infeed The UVairo Air Sanitizer uses forced air for both cooling the UV C lamps and for feeding air into the UV C box Air Filtration The air filter is located at th...

Страница 8: ...han those specified for plastic are used Recommend using Geerpres Advantex Single Use Microfiber wipes for cleaning CAUTION Do not use any type of caustic cleaner or solvent type cleaner on the polycarbonate doors of the machine nor any type of Scotch Brite material or equivalent Stainless Steel Cleaning Use soft white cloths and a specific high quality stainless steel cleaner to avoid scratching ...

Страница 9: ...CE Changing the Lamps 1 Disconnect the power and allow the unit to cool 2 Open the top of the unit by unscrewing the four screws 3 Remove the top cover Continued on the next page Location of Screws Top Lifted Off ...

Страница 10: ...t doesn t connect slowly rotate until the pins align and the lamp drops in to place Press firmly to secure it Continued on the next page Firmly Grasp the End of a Lamp Slightly Rectangular Lamp Plug 1 Disconnect the Lamps a Firmly grasp a lamp b Lift lamp out of its pocket CAUTION Do not twist the lamp when pulling out Sheering of the lamp pins mayoccur ...

Страница 11: ...he unit back in 3 Turn on the power switch 4 Visually inspect Are all lamps lit after 30 seconds If not disconnect the machine remove top and inspect the lamp connections Note You can safely look into this machine when the top cap is on the machine CAUTION NEVER look directly into the machine with the top cap lifted off ...

Страница 12: ...ere are a few thin openings Use a thin firm object like a ruler or credit card to press on the filter and push it out a couple inches so that it can be removed from the other side Pull the filter out Orient the new air filter according to the air flow arrow It should be pointing upwards Gently slide the new filter into the spring loaded filter retainer ...

Страница 13: ...the On Off switch and the power cord plug in is a fuse insert Unplug the cord from the wall and from the machine pry open the fuse insert from inside the power cord plug in and replace the fuse Fuse in the Insert Fuse Location Pry out the Fuse Insert ...

Страница 14: ...lter Change Change the air filter at least every 3 months Yearly Maintenance Lamps Change Change the lamps every year at a minimum Their effectiveness reduces after approximately 9000 hours of use one year based on a 24 7 run schedule 14 Geerpres Part Kit Qty 560600UV 4 560600F6 2 560600C4 4 560600SV 1 Annual Service Kit 4 Lamps and 12 Filters Filters Caster Item UV C Lamp ...

Страница 15: ...pres has a history of providing innovative cleaning products and supplies Our high quality stainless steel cleaning products offer superior antimicrobial properties required in the healthcare environment In business for over 85 years Geerpres EVS carts steel wringers and seamless buckets have been the industry standard in environmental services including hospitals cleanroom critical environment fo...