Maintenance – Checking – Cleaning
Assembly and instruction manual
90 / 124
BL164 GB Edition 07/2017
9.1.1
Documenting the results
The operating company must document the results of the checks.
The documentation must be kept for a reasonable period of time –
however at least for the entire lifetime of the device.
•
The results of the recurring check can be recorded in writing in the
appendix of this manual.
•
Verification confirming that the last inspection was executed must be
attached to the device.
9.1.2
Checks before initial operation
Checks at the factory
The following tests have already been carried out at the factory:
•
Dynamic test with 1.1x useful load.
•
Electrical tests according to EN 60204.
•
Examination of operation.
9.1.3
Checks after assembly / daily before starting operation
To guarantee safety when handling the device, the person appointed by
the operating company is obliged to carry out a daily inspection of
certain device areas / parts.
Defects detected must be immediately reported to the supervisor and
rectified. Defects may only be rectified by trained personnel responsible
for maintenance and servicing.
Always carry out visual inspections before function checks. Operation is
prohibited until the defects are rectified.
The following points must be checked daily
•
Visual check before start of work
→
refer to Chapter “Operation”
•
Clean the base unit (keep free from snow and ice in winter).
•
Keep work area around the device clear and clean.
For checks after each installation
→
refer to Chapter “Assembly”.
9.1.4
Recurring checks
Recurring checks must be carried out in accordance with national
regulations.
GEDA recommends that you carry out a recurring check on an
annual basis. In the event of increased demand, carry out checks
at shorter intervals.