GEDA
®
3700 Z/ZP
Assembly
ML034 GB 2017 / 11
Page 39 of 60
Assembly Instructions
6.8.1
Assembling mast sections
Load the platform with mast sections, parts for mast tie and tools.
(max.
1000 kg)
.
Close the platform access of the ground station from the inside.
Open barriers, door or assembly guard must be closed. They
interrupt the control.
Switch the platform control to “Assembly” mode
(see section 6.2).
Press the
UP
button (on the platform control).
Platform stops at the top of the mast.
Assembly guard
Opening
Slightly raise the assembly guard
(1), pull forwards and lower.
Closing
Lift up the assembly guard (1), push towards the mast and hook to the
platform frame.
The open assembly guard interrupts the safety circuit. The platform
cannot be moved whilst the assembly guard is open.
1