Malfunctions - Diagnosis – Repair
GEDA
®
1500 Z/ZP
Operating Manual
80 / 84
BL076 GB Edition 07.2015
5.4.2
Rescue action plan
Action 1:
Check the operating mode.
Somebody might have inadvertently turned the key switch
on the platform.
Turn the key switch (5) to position
I.
Press the
UP
button (3) or the
DOWN
one (4) to continue travel.
The platform moves.
Action 2:
Self-rescue using
EMERGENCY lowering.
The
EMERGENCY
descent function is used only in an emergency to
reach the next lowest landing. Hereby, persons trapped can evacuate
themselves
WARNING
Trigger the safety gear
The brake release lever must be operated extremely
carefully to prevent the safety gear from engaging. If the
safety gear has engaged once, it will not be possible to
progress any further without raising the platform.
2 = Cable to release brake
2
5
3
4