GEDA
®
1500 Z / ZP
Page 98 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
18.4
Replenishment and inspection tasks
18.4.1
Lubrication device
Replenishing through the nipple
Place the grease gun to the nipple (1)
(Underside of the container).
Fill reservoir to the “MAX” mark.
Quick-filling with a filling gun
Remove the cap from the filling
connection (2).
Insert the grease gun up to the stop
point inside the filling connection.
Fill reservoir to the “MAX” mark.
The function of the lubrication device
can be checked using the button (4).
Bleeding the lubrication device
If the limit switch is defective, the lubrication device will run completely
empty and must be bled after the limit switch has been repaired / replaced.
Place the grease gun on the nipple (1).
Fill up to 4 cm above the “MIN” mark.
Remove the lubrication hose from the pump housing.
Remove the pump element or locking screw (M20x1.5) and keep open
until bubble-free grease is discharged.
Install the pump element or locking screw.
Activate a lubrication pulse until bubble-free lubricant discharges.
Reconnect the lubricating hose.
CAUTION
Do not use grease with solid lubricants. This could damage the
lubrication device.
2
3
1
4