GEDA
®
1500 Z / ZP
Page 88 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
Secure the telescopic tube (5) to the inside of the circular mast tube
with a rigid scaffold coupling, pulling it towards the wall and anchoring it
there. Select the furthest possible horizontal distance between the two
anchoring tubes against the wall. (The minimum distance between the
two fastening plates is dependent upon the distance between the mast
and building, and extension tubes should be used with greater
distances).
The vertical and rectangular alignment of the mast must be checked and
corrected if necessary.
The mast is vertically aligned by shifting the anchoring tubes in the
mast bracket or scaffold coupling.
Right-angled alignment of the mast is by using both scaffold
couplings (4).
The anchoring for the left mast will be attached at the same height,
inversely to the right mast anchoring described above.
NOTE
In order to keep wear of the gear racks as low as possible, we recommend to
lubricate the gear racks each time a mast bracket is assembled.