GEDA
®
1500 Z / ZP
Page 67 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
12.1.2
Function tests
Test run with empty platform
Unusual odours, noises and vibrations.
Oil/grease
leaks.
Move the platform to the maximum height.
- Stop the platform at the correct position.
- Further upwards movement is not possible.
Move the platform to the ground station.
- Stop the platform at a height of 2m, an acoustic warning signal is
emitted, further movement to the ground station is only possible in
deadman mode.
- Stop the platform at the correct position.
- Further downwards movement is no longer possible.
12.1.3
Test run by platform operator/person authorised to carry out
tests and inspections
No one else is allowed to be in the platform.
Move to each stop position.
Stop the platform inside the tolerance range max. ± 2 cm
Platform access and landing level safety doors are functioning
properly.