Geco GH10TA Скачать руководство пользователя страница 1

 

                                                         

                          

           

 

 

 

 

MANUAL 

FOR CONTROLLER  

 

GH10TA 

 

 

FOR CONTROLLING 

CENTRAL HEATING BOILERS 

WITH PISTON FEEDER 

 

Program version: 03a 

 

 

 

USER MANUAL 

 

 

 

We request that users carefully study applicable Instructions before connecting and  

starting up any of our products.  

Should any doubts arise, please contact our Company between 8 a.m. and 4 p.m. 

Attention !!!  At the bottom of each page you will find last document’s update date. Please, always use the 

most recent version of the Instructions, which is available free of charge and will be mailed to you if ordered.

Содержание GH10TA

Страница 1: ...licable Instructions before connecting and starting up any of our products Should any doubts arise please contact our Company between 8 a m and 4 p m Attention At the bottom of each page you will find...

Страница 2: ...BOILER BURNOUT DETECTION 13 6 8 MAXIMUM FEEDER TEMPERATURE DETECTION 13 7 USER SETTINGS 14 7 1 BOILER TEMPERATURE SETTING U0 14 7 2 FEEDER STANDSTILL DURATION U1 14 7 3 MAINTAIN PERIOD U2 14 7 4 FAN S...

Страница 3: ...ation have the following graphic forms Warning This symbol is used when it is necessary in described instructions to follow the sequence of carried out operations The unit may be damaged or destroyed...

Страница 4: ...BY USING BUTTON ACTIVATE ALL BUTTON ON PANEL TOUCH KEYBORD TAKES PLACE AFTER TOUCH EACH OF THEM AND HOLD FOR MOMENTS ON OFF MANUAL CONTROL AUTO OPERATION INDICATOR MANUAL FAN AND CH PUMP ACTIVATION IN...

Страница 5: ...s and other different disturbances The GH10TA Controller is fitted with inputs 1 boiler output water temperature measurement NTC sensor 2 fuel feeder temperature measurement NTC sensor 3 HUW boiler re...

Страница 6: ...g varistor Omission of this security measure may result in malfunction or damage to the controller output 4 ELECTRICAL SYSTEM AND CONNECTION RULES 1 The boiler room should be equipped with a 230V 50Hz...

Страница 7: ...d After calibration process the device performs a 3 second start sequence during which it displays various information including the firmware version When the start sequence is complete the controller...

Страница 8: ...ory settings Table 1 Factory settings table Parametr Opis parametru Min Max Krok Nastawa fabryczna U00 Boiler temperature setting F03 F04 1 C 60 C U01 Feeder standstill duration 5 250 1s 30s U02 Maint...

Страница 9: ...ral Heating cycle HUW cycle INPUTS OUTPUTS T1 Boiler temp P1 Fuel feeder T2 Feeder temp P2 Fan T3 HUW temp P3 HUW pump C1 Reed relay P4 CH pump 6 1 2 Central Heating cycle mixing pump INPUTS OUTPUTS T...

Страница 10: ...40 C Turning the CH pump on and its operation is indicated by a vertical line at the left side of the Controller main display screen The Controller turns off the pump when the water temperature drops...

Страница 11: ...pump is indicated by a horizontal line at the bottom of the Controller main display screen Pressing causes the Controller to switch from automatic to manual mode and immediately stops the fan the feed...

Страница 12: ...HUW return temperature sensor failure AL9 No feeder rotation reed switch failure AL11 Maximum feeder temperature exceeded AL12 Boiler overheating AL13 Boiler burnout 6 6 Power Failure After a power fa...

Страница 13: ...er enters the AL13 alarm condition 6 8 Maximum Feeder Temperature Detection The GH10TA Controller is equipped with an additional option of protecting from temperature rise in the fuel feeder above the...

Страница 14: ...U2 setting 7 3 Maintain Period U2 This is the period of time after which the Controller activates the feeder and fan for the period set by the manufacturer for the MAINTAIN mode to prevent burning ou...

Страница 15: ...th Legionella pneumophilia bacterium on HUW installation This function is available for users when value F00 service parameter was adjust on 02 03 or 04 The Legionella bacterium growth in water enviro...

Страница 16: ...dure allows you to connect an additional pump that can be used as a mixing pump or a Hot Utility Water HUW pump operating with or without higher priority The HUW pump is started when the boiler outlet...

Страница 17: ...room During blockade position C H pump stay off after 4 minutes for the moment when temperature in room is reached short circuit contact The boiler start working in maintain operation mode The contro...

Страница 18: ...Controller to resume operation you have to after resetting the limiter press twice pressing for the first time cancels the alarm and disables the Controller pressing for the second time reactivates t...

Страница 19: ...RICAL AND ELECTRONIC EQUIPMENT CAUTION This symbol placed on the product or its packaging indicates the need for selective collection of worn out electrical and electronic equipment It means that this...

Страница 20: ...P P U H Geco Sp z o o Cholerzyn 376 32 060 Liszki Poland ph 012 636 98 11 636 12 90 fax 012 636 20 02 http www geco pl e mail geco geco pl...

Отзывы: