SERVICE OPERATING MANUAL  

FOR INDEPENDENT CONTROL  

UNIT  

  

G-201-P00… 

 

 

VERSION FOR COOLING APPLIANCES  

 

For software version 01,02 

 

You are kindly asked to study instructions carefully before connecting and starting up each of 
our appliances. If you have any doubts, please contact us from 8.00 till 16.00. Any remarks 
sent to us by e-mail shall be a valuable help.  
 

Notice !!!   At the bottom of the following pages the date of the latest updating is given 
and at the end of page XVI there is information on the changes in program versions and 
the mode of operation that followed.  
 
You are asked to use always the newest version of operating manual which can be received 
free of charge by mail after submission of an order. 

Содержание G-201-P00 Series

Страница 1: ...connecting and starting up each of our appliances If you have any doubts please contact us from 8 00 till 16 00 Any remarks sent to us by e mail shall be a valuable help Notice At the bottom of the fo...

Страница 2: ...RKING AND TECHNICAL DATA Model G 201 P 00K X X M XX00 0 Position 1 2 3 4 5 6 7 8 9 10 11 12 1 Geco thermostat 2 Use in refrigeration 3 Casing 01 minipanel 4 The beginning of symbols related to panel c...

Страница 3: ...mostat that controls operation of the compressor and lighting G 201 P00K00 M1200 0 Thermostat that controls operation of the compressor and of an additional appliance a ventilator a heater or a valve...

Страница 4: ...t load 16A They are provided with fine thread and special plates preventing cutting of cables therefore when lightly screwed together they will have maximally good contact and if more force is applied...

Страница 5: ...unit 3 Evaporator sensor should be fixed in the way which assures maximally good and sure contact with the evaporator slat and in the place where ice keeps longest during defrosting Its fixing should...

Страница 6: ...ing pressing of any button is signalled by a short sound 3 Programming of temperature When is pressed programming mode begins the value of a parameter appears on the display and a diode at the button...

Страница 7: ...egin to flash and show evaporator temperature after the following 5 seconds G 201 will show chamber temperature again Notice This function works also during defrosting when dF appears on the display C...

Страница 8: ...ed display case plus temperatures I demand that the unit allow operation within the range of values given below off min 2 C on max 10 C symmetrical hysteresis for even values of d3 asymmetrical hyster...

Страница 9: ...O R sto p o p e r a tio n D E F R O S T IN G E N D O F D E F R O S T IN G o p e r a tio n sto p 2 ventilator which operates all the time r1 02 t 0 c 3 o f n o im p o rta n c e C O M P R E S S O R V E...

Страница 10: ...When this activity is done diodes on buttons and will flash and symbol c0 will appear on the display for 1 second Then the latest programmed value of the parameter will appear Now using buttons the n...

Страница 11: ...stoppage time with damage of control sensor 1 60 1min 5min d0 Minimal temperature for a client to set 40 20 1 C 1 C d1 Maximal temperature for a client to set d0 1 40 1 C 10 C d2 Evaporator temperatu...

Страница 12: ...f the sensor is fixed correctly the condition of the cable of the sensor the cable can not have any defects in detail the lookout of external surface of sensor shell to see whether it has not been dam...

Страница 13: ...DEFINED THEN AS PARAMETER d2 9 The appliance does not reach the set temperature and does not cool Check what temperature was programmed by the user set values of particular parameters in particular c2...

Страница 14: ...the unit if there is no form the form is not filled in completely or the seals are broken P P U H Geco Sp z o o is not responsible for loses and damages resulting from provision of information on the...

Страница 15: ...9811 fax 6362002 www geco pl e mail geco geco pl WIDOK Z G RY WIDOK Z PRZODU G 201 P00K00 M1000 Un 230V 50Hz Imax 10A P1 WIA O 2A 750W P2 KOMPRESOR 8A 2HP 1500W P P Czujnik PAROWNIKA SZARY K K Czujnik...

Страница 16: ...SERVICE MANUAL FOR PRODUCERS SBR TYPE G 201 P00 PPUH GECO G 201 P00 01 02 PRINTOUT DATE 05 01 24 widok z g ry view from above w z przodu front view czujnik komory chamber sensor cz Parownika evaporato...

Страница 17: ...Switching on off of lighting Pressing of the button causes switching on off of the light It is signalled by a green diode at the button The button works independently of the thermostat switch 4 Switch...

Страница 18: ...page 18 SERVICE MANUAL FOR PRODUCERS SBR TYPE G 201 P00 PPUH GECO G 201 P00 01 02 PRINTOUT DATE 05 01 24...

Страница 19: ...NUMBER TYPE G COOLING UNIT DATA PRODUCER TYPE COMPRESSOR TYPE SERIES NUMBER PRODUCTION DATE DETAILED DESCRIPTION OF DEFECT OF INDEPENDENT CONTROL UNIT DESCRIPTION OF COOLING UNIT DEFECT DAMAGED COMPR...