SOFTWARE MANUAL C32
6 PRINTER INITIALIZATION
[Name]
Initialize Printer
[Format]
ASCII
<RS>
<DLE>
n
Hex
1Eh
10h
n
Decimal
30d
16d
[Description]
0: A
Restarting the system (PoR) while avoiding the bootloader
Standard RESET
1: A
Restarting the system (PoR) with default bootloader properties
2: A
Restarting the system (PoR), with enforcing the bootloader to wait for commands (using time-out)
3: A
Restarting the system (PoR), with enforcing the bootloader to wait for commands (using time-out)
4: A
Shut-down the system (deactivate Vcc_enable) = Power OFF
5: A
Erasing all buffer contents of the renderer and of all print instructions
6: A
Erasing all tickets not yet started
7: A
Abortion of the ticket being printed
8: A Abortion of data download asynchronous – acts directly
9: S Abortion of data download synchronous to print data
10: S
Restarting the system (PoR) while avoiding the bootloader
11: S
Restarting the system (PoR) with default bootloader properties
12: S
Restarting the system (PoR), with enforcing the bootloader to wait for commands (using time-out)
13: S
Restarting the system (PoR), with enforcing the bootloader to wait for commands (using time-out)
14: S Shut-down the system (deactivate Vcc_enable)
15: A Erasing actual print line
16: A Restarting the system without PoR
17: S Restarting the system without PoR
18: A Erasing EEPROM parameters
19: S Erasing EEPROM parameters
20: A Abortion of template being printed, rasing all tickets not yet started
n:= 255d Restarting the system (PoR), with enforcing the bootloader to wait for commands (without time-out)
S:
Command is synchronously executed with data stream
A:
Command is asynchronously executed, as soon as possible
GeBE Elektronik und
phone
+49.89.894141-0
GeBE-document-no. SoMAN-C32-E-V2.2-0793
Feinwerktechnik GmbH
fax
+49.89.894141-33
date
July 7, 2020
Beethovenstraße 15
page 32 | 166
82110 Germering
Our general terms of business are to be applied.
Germany
Internet
www.gebe.net
Errors and changes reserved.