The  DC2 ”S“ is a modern and safe alternative to conventional control gear. For ope-
ning or closing of the door the drive unit is activated through a handtransmitter
(radio control) or through a push-button on the housing.

After pushing of the push-button or the handtransmitter the door is triggered UP or
DOWN.

Technical Data:

Supply voltage               

230 V AC 50 Hz

Output

2x relay contact, 5 A / 230 V 
1x relay contact, 2 A / 230 V
1x supply Voltage 24V/50mA

Connections

1.5 mm

2

max., 

Ambient-

-20 ˚C to +60 ˚C

temperature

geba GmbH is released of its obligations regarding guarantee and product liability if - without
prior permission - the unit has been modified, or if the installation is improper or not in accordance
with our instruction manual.
The installer has to take care that the EMC-regulations are respected.

GB

The most important characteristics of the DC2 ”S“  are:

Simple operation, programming and assembly.

Water-protected enclosure.

A maximum of safety:

➢ 

The electronic decoder is separately installed in the protected area

➢ 

Nearly unlimited data security, even with power failure

➢ 

Direct connection to safety edge

➢ 

Rolling code transmitter

High switching capacity for direct control of appliances
24V / 50 mA output for lphoto beam

industrial controls

®

industrial controls

®

Service display
The 4 most likely faults are indicated by the service display lamp by means of a
simple flashing code system as below:

1x flash

safety edge defect

2x flash

limit switch not reached 
or defect

3x flash

pre-limit switch defect

steady glow

safety edge activated