background image

AEH24

AEW24

Safety Instructions

 . . . . . . . .2, 3

Operating Instructions

 . . . . .4, 5

Care and Cleaning

Air Filter  . . . . . . . . . . . . . . . . . .6
Grille and Case  . . . . . . . . . . . . .6
Outdoor Coils  . . . . . . . . . . . . . .6

Installation Instructions

 . .7–12

Troubleshooting Tips

 . . . . . .13

Normal Operating Sounds  . . .14

Consumer Support

Consumer Support  . . . . . . . . .18
Product Registration  . . . . .15, 16
Warranty  . . . . . . . . . . . . . . . . .17

49-7502

02-05 JR   

Owner’s Manual and

Installation Instructions

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the
side of the air conditioner.

A

ir Condit

io

ners

Room

www.GEAppliances.com

Содержание AEH24

Страница 1: ...13 Normal Operating Sounds 14 Consumer Support Consumer Support 18 Product Registration 15 16 Warranty 17 49 7502 02 05 JR Owner s Manual and Installation Instructions Write the model and serial numbers here Model __________________________ Serial __________________________ Find these numbers on a label on the side of the air conditioner Air Conditioners Room www GEAppliances com ...

Страница 2: ...der any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of electric shock hazard from this appliance Power cord includes a current interrupter device A tes...

Страница 3: ... grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug with the other han...

Страница 4: ...AVER Controls the fan ON The fan will cycle on and off with the compressor This results in wider variations of room temperature and humidity Normally used when the room is unoccupied NOTE The fan will continue to run for a short time after the compressor cycles off OFF The fan runs all the time while the compressor cycles on and off This feature must be set at OFF in order to use the fan settings ...

Страница 5: ...erature NOTE If you switch from a COOL setting to OFF or to a fan setting wait at least 3 minutes before switching back to a COOL setting FAN Mode Use the FAN at HIGH MED or LOW to provide air circulation and filtering without cooling Since fan only settings do not provide cooling a temperature setting will not be displayed Consumer Support Troubleshooting Tips Operating Instructions Safety Instru...

Страница 6: ...frame while pressing in on the case side tabs with your finger tips Pull out to release and lift it up NOTE Do not pull the bottom edge toward you more than 3 or you may damage the tabs of the grille Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning To clean use water and a mild detergent Do not use bleach or abrasives Care and cleaning of the ai...

Страница 7: ...with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possible fire hazard from overheating wires ELECTRICAL REQUIREMENTS CAUTION Do not under any ci...

Страница 8: ...ocking bracket 2 Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 4 Type C 7 Type D 6 Type E 6 Bolt 2 nuts 2 PARTS INCLUDED Appearance may vary 8 Installation Instructions ...

Страница 9: ...H Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securely with nails or screws provided by the installer 1 2 higher than frame Storm window frame Wood Stool 2 REMOVE THE AIR CONDITIONER FROM THE CASE Remove the 2 shipping screws if present from the back of the cas...

Страница 10: ...NSTALL THE CASE IN THE WINDOW Carefully slide the case into the window and center the case Lower the window behind the top mounting rail Pull the bottom of the case forward so that the bottom mounting rail is tight against the back of the window stool Mount the case to the window sill using 4 type E screws Drill pilot holes if necessary Make sure the bolts and nuts are all of the way in both the l...

Страница 11: ...f the weight of the air conditioner falls between the studs in the wall Extend the left and right accordion panels to the vertical window sashes Drill pilot holes and attach the top and bottom corners with 4 type D screws F E D 6 Type D screw Type D screw Type D screw Top mounting rail Type D screw INSTALL SUPPORT BRACKETS AND THE FOAM TOP WINDOW GASKET Attach the support brackets with two type E ...

Страница 12: ...hook it from its top hinges and set it aside Using the tab pull up slightly on the filter to release it and pull it down and out F E D C B A 8 Installation Instructions 12 INSTALL THE AIR CONDITIONER IN THE CASE cont Pull the coiled power cord from its shipped position in the air discharge area Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on th...

Страница 13: ...wn Cold air is escaping Check for open furnace floor registers and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice blocks the air flow and Set the controls at HIGH FAN or HIGH COOL and set the freezing up stops the air conditioner thermostat to a higher temperature from cooling the room The ...

Страница 14: ...cked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit The fan may run even when the compressor...

Страница 15: ... protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that al...

Страница 16: ...ere Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 432 2737 Read your Owner s Manual carefully It wil...

Страница 17: ...ovide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of God Incide...

Страница 18: ...arn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their home...

Страница 19: ...idos normales de operación 14 Apoyo al consumidor Apoyo al consumidor 18 Garantía 17 Escriba los números de modelo y serie aquí de Modelo ___________________ de Serie _____________________ Puede encontrar estos números en una etiqueta en el costado del acondicionador de aire Manual del propietario e Instrucciones de Instalación Acondicionadores de Aire www GEAppliances com AEH24 AEW24 49 7502 02 0...

Страница 20: ...asura para que le indiquen qué hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o remueva la tercera púa tierra del cable eléctrico En pos de la seguridad personal este electrodoméstico debe siempre conectarse a tierra El cable eléctrico de este electrodoméstico está equipado con un enchufe de tres púas tierra que combina con un tomacorriente estándar de tres tomas de pared para mi...

Страница 21: ...isponible en la mayoría de las ferreterías La ranura mayor en el adaptador debe estar alineada con la púa mayor en la pared para proporcionar una polaridad apropiada en la conexión del cable eléctrico Cuando se disponga a desconectar el cable eléctrico del adaptador siempre sostenga el adaptador en su lugar con una mano mientras tira del cable eléctrico con la otra mano Si no hace esto la terminal...

Страница 22: ...s de que el compresor haya entrado en el ciclo de apagado OFF APAGADO El ventilador funciona todo el tiempo mientras que el compresor pasa por los ciclos de encendido y apagado Este interruptor debe estar en OFF APAGADO para usar los ajustes del ventilador en el control de modo CIRCULAIRE Para proporcionar circulación de aire continua de lado a lado ajuste el interruptor de Circulaire en ON ENCEND...

Страница 23: ...de ventilador espere aproximadamente 3 minutos antes de cambiar otra vez al ajuste de COOL FRÍO Modo de FAN Ventilador Use el FAN Ventilador en High ALTO MED MEDIO o LOW BAJO para proporcionar circulación de aire y filtración sin enfriamiento Debido a que los niveles de ventilador únicamente no proporcionan enfriamiento el nivel de temperatura no se muestra en la pantalla Control de la ventilación...

Страница 24: ...l tomacorriente de la pared antes de limpiar Para limpiar use agua y un detergente suave No use cloro o materiales abrasivos Cuidado y limpieza del acondicionador de aire 6 Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación Retirar el marco de la rejilla si es necesario para limpiar las bobinas Agarre las esquinas inferiores del marco de la rejilla mientras presiona hacia ade...

Страница 25: ...ondicionador de aire Los cables caseros de aluminio podrían presentar problemas especiales Consulte a un técnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidadosamente IMPORTANTE Guarde estas instrucciones para uso del inspector local IMPORTANTE Observe todos los códigos y órdenes de ley Nota al instalador Asegúrese de dejar estas instrucciones con el consumidor...

Страница 26: ...a ventana Panel de acordeón izquierdo PARTES INCLUIDAS apariencia puede variar Instrucciones de instalación 8 HERRAMIENTAS QUE NECESITARÁ Un destornillador de estrella Una regla o cinta métrica Lápiz Nivel Tijeras o cuchilla Un destornillador con hoja plana Apoyo en V Llave ajustable Perno 2 tuercas 2 Tipo A 6 Tipo B 4 Tipo C 7 Tipo D 6 Tipo E 6 ...

Страница 27: ...gitud para ajustarse al interior del marco de la ventana ESPESOR Para determinar el espesor coloque un pedazo de madera en la repisa para hacerlo 1 2 más alto que la parte superior del marco de la ventana de tormentas Una firmemente con puntillas o tornillos provistos por el instalador 1 2 más alto que el marco Marco de ventana de tormentas Madera Repisa 2 RETIRE EL ACONDICIONADOR DE AIRE DE LA CA...

Страница 28: ...ENTANA Con cuidado deslice la caja en la ventana y céntrela Baje la ventana detrás del riel de montaje superior Tire del fondo de la caja hacia adelante de forma tal que el riel de montaje del fondo quede apretado contra la parte posterior de la repisa de la ventana Monte la caja en el umbral de la ventana usando 4 tornillos tipo E Taladre agujeros pilotos si es necesario Asegúrese de que los pern...

Страница 29: ...o del acondicionador de aire cae entre columnas en la pared Extienda los paneles de acordeón izquierdos y derechos al marco vertical de la ventana Taladre agujeros pilotos y pegue las esquinas superiores y inferiores con cuatro tornillos tipo D F E D 6 Tornillo tipo D Tornillo tipo D Tornillo tipo D Riel de montaje superior Tornillo tipo D INSTALE SOPORTES DE CIERRE Y LA JUNTA DE ESPUMA SUPERIOR D...

Страница 30: ...a hacia adentro INSTALE EL ACONDICIONADOR DE AIRE EN LA CAJA Deslice el acondicionador de aire en la caja No empuje los controles o las bobinas de aleta Asegúrese de que el acondicionador de aire esté firmemente asentado Reinstale el soporte de cierre y el tornillo retirado anteriormente Vuelva a conectar el cable de conexión a tierra al acondicionador usando el tornillo retirado anteriormente IMP...

Страница 31: ...a calefacción no están abiertos y se encuentran retornando el aire frío Coloque la ventanilla del acondicionador de aire en la posición cerrada Las bobinas de enfriamiento Ver Acondicionador de aire congelándose más adelante se congelaron El acondicionador de aire El hielo bloquea el flujo Coloque los controles en HIGH FAN VENTILADOR ALTO se está congelando de aire hacia el acondicionador ó HIGH C...

Страница 32: ...yuda a remover la humedad y mejora la eficiencia Quizás escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante días lluviosos o con mucha humedad El agua podría derramarse y gotear desde el lado externo de la unidad El ventilador podría funcionar aun si el compresor no lo hace Apoyo al consumidor Solucionar problemas Op...

Страница 33: ...15 Notas Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación ...

Страница 34: ...Notas Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación 16 ...

Страница 35: ...rio En locales comerciales la mano de obra necesaria para retirar la unidad hacia un lugar para revisión por parte de un técnico individual Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallos debido a la corrosión en modelos que no están protegidos contra la corrosión Daño al producto causado por voltaje inapropiado hacia el equipo accidentes incendios inundaciones o actos ...

Страница 36: ... mientras su garantía está aún activa Puede comprarla en línea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios www GEAppliances com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos pueden pedir que se les manden las piezas o accesorios ...

Отзывы: