6.6.9
Fitting to an ASEPTOMAG Valve
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Notice
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
► Protect the permanent magnet against impact stress.
Notice
Magnetic fields resulting from the permanent magnet on the
switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or
mechanical components.
► Protect the components against the magnetic fields from the switch bar.
Carry out the following steps:
1.
Place the T.VIS mounting base (M), with O-rings (M1), on the actuator (A.4)
and secure it with four M5 screws (M.2).
Fig.40
2.
Screw the switch bar (4) Mat. 221-589.87, into the piston rod (A4.1) and
tighten with open-end wrench SW 13, torque 3 Nm.
3.
Fit the control top (B) over the switch bar (4) and on the actuator.
4.
Tighten the clamp connection (15) and screws (39) to a torque of 1 Nm.
5.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
!
As internal air guiding is not possible for ASEPTOMAG valves, connect the
air connection (Y1) on the control top to connection (A.4.2) on the actuator
with an air hose (L).
Assembly and installation
Mounting the Control Top to Different Valves
430BAL010697EN_2
15.04.2020
71
Содержание T.VIS M-15
Страница 6: ...430BAL010697EN_2 6 15 04 2020...
Страница 53: ...Fig 27 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 53...
Страница 55: ...Fig 28 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 55...
Страница 111: ...14 Spare parts list Switch bar T VIS M 15 Fig 82 Spare parts list Switch bar T VIS M 15 430BAL010697EN_2 15 04 2020 111...
Страница 119: ...Appendix 430BAL010697EN_2 15 04 2020 119...
Страница 120: ......