6.6.6
Mounting to VESTA Valve H_A
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Notice
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
► Protect the permanent magnet against impact stress.
Notice
Magnetic fields resulting from the permanent magnet on the
switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or
mechanical components.
► Protect the components against the magnetic fields from the switch bar.
Carry out the following steps:
1.
Place O-rings (139.2) in the adapter (139) at the bottom side of the thread
(139.1).
Fig.36
2.
Screw the adapter into the actuator (A4.1) and tighten using an a/f 17 open
end spanner.
3.
Complete the T.VIS mounting base (198) with O-rings (29, 101) and a plain
bearing (202).
4.
Screw the mounting base (198) into the actuator (A4) and tighten using a face
spanner.
Assembly and installation
Mounting the Control Top to Different Valves
430BAL010697EN_2
66
15.04.2020