6.3.3
Control top with 3 solenoid valves
Hint!
To ensure sufficient compressed air supply to the process drives, a
maximum of 2 solenoid valves are electrically controlled at the same
time! It must be ensured that no simultaneous control of the drive or
the lifting can take place at the same process valve!
Only two solenoid valves may be operated at the same time
The simultaneous operation of more than two solenoid valves will increase
the temperature to a critical and non-certified level.
► The conditions of use in chapter 2.3 must be observed.
Fig.16:
Control top (standard variant in IP 66)
E1
Exhaust air of the main stroke Y1 (sound absorber or exhaust air
throttle, optional)
Connection E1 must not be closed!
E2
Safety vent against excess pressure and exhaust air of lifting
actuators Y2 and Y3
Non-return valve
Connection E2 must not be closed!
P
Central air supply with integrated filter
optional: supply air throttle
N
not available
Y1
Air connection for external main stroke connection
with plug (23)
Y2
Air connection for lifting the valve disk
Assembly and installation
Pneumatic connections
430BAL013985EN_6
50
25.04.2023