10.4.7 Installation instructions
Notice!
Hygiene risk, food safety
Incorrect installation of the pump can cause subsequent contamination and
thus impair food safety.
► Always observe the following instructions:
– Use tools from the HILGE assembly tool kit for installation.
– Check removed parts for damage and wear, and replace if necessary.
Use only proper, clean parts for installation. Clean installation space and
contact surfaces before installation.
– Always use original spare parts.
– Only use certified original spare parts for 3-A applications.
– Use no mineral oil greases for the wet section assembly.
– Always replace mechanical seals completely.
– Remember the properties when replacing the O-rings. See
– Use a screwdriver or an impeller nut mounting device to tighten the
impeller nut (0922.00).
10.4.7.1 Cleaning the components before assembly
Notice!
Hygiene risk, food safety
Contaminated components contaminate the pump and installation.
► Use suitable chemical cleaning agents to remove impurities in the area of
the impeller area, the O-rings or the mechanical seal. Use a brush and / or
other tools in order not to damage the surface. Plan contact-free cleaning in
an ultrasonic bath to clean the mechanical seal.
Malfunctions / repairs
Repair
BA.H2A.ADY.002.GB_1
18.12.2017
57