The O-ring has cracks.
–
The surface of the O-ring is porous and brittle.
–
The O-ring has lost its elasticity.
9.3.2
Maintenance intervals
To ensure the highest operational reliability of the magnetic separator, all wearing
parts should be replaced at longer intervals.
The actual maintenance intervals can only be determined by the user since they
depend on the operating conditions, for instance:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
Maintenance intervals
Applications
Maintenance intervals
(guideline values)
Media at temperatures of
60 °C to 130 °C
(140 °F to 266 °F)
approx. every 3 months
Media at temperatures of
< 60 °C
(< 140 °F)
approx. every 12 months
9.4
Maintenance of the ADAPTA bearing
9.4.1
Bearing carrier structure sizes 1 and 2
The bearing structure consists of two angular contact ball bearings. They are
paired and are installed as fixed bearings in an O-arrangement to accommodate
axial and radial forces from all directions.
Grease quantities for roller bearings during installation
The information refers to a complete filling of the bearings.
Grease quantities for installation
Size
1
2
Part no.
0326.00
0326.00
Number of bearings
2
2
Volume [cm
3
] per bearing
9
25
Quantity [g] per bearing
8.5
23.7
Maintenance / servicing
Maintenance of the ADAPTA bearing
BA.H2A.ADY.002.GB_1
44
18.12.2017