Warning!
Pressure shock by evaporating liquid!
► Completely empty the system before steam sterilisation.
Notice!
Disposal of cleaning agents
► Dispose of cleaning agents properly and in an environmentally friendly
way.
8.3
CIP
CIP stands for Cleaning in Place, the pump is completely rinsed with cleaning
agents. The cleaning agent used must be suitable for the respective cleaning
task.
The following table lists approved detergents and disinfectants and their
permitted concentrations. Alternatively, information from DIN11483 Part 1 can be
used.
Cleaning and disinfecting agents
Cleaner type
Chemical
name
Max.
concentration
Max.
temperature
Permissible
pH
Max.
permissible Cl
content in the
preparation
water
Max.
permissible
contact time
[%]
[°C] (°F)
[mg/l]
[h]
Alkaline
NaOH
2.5%
85 (185)
1
13-14
150
3
Acid
H
2
SO
4
H
3
PO
4
HNO
3
2%
2
,
3
60 (140)
150
4
,
5
1
C
2
H
4
O
3
0.0075%
90 (194)
150
0.5
C
2
H
4
O
3
0.15%
20 (68)
150
2
Iodophore
50 mg/l act.
Iodine
30 (86)
>3
150
3
Cleaning agents that contain hydrochloric acid (HCl) or hydrofluoric acid (HF)
must not be used. Consult the supplier for the use of special cleaning agents and
procedures with respect to the materials. Thoroughly rinse the pump with water to
remove any cleaning agents leaving no residues. For the maximum allowable
temperatures, refer to Section 5.4, Page 23.
1
Dependent on the maximum permissible temperature of the pump
2
CrNi-steels
3
CrNiMo-steels
4
CrNi-steels
5
CrNiMo-steels
Cleaning
CIP
BA.H2A.ADY.002.GB_1
18.12.2017
41