10.4.11 Fasten discharge casing - simple mechanical seal
Equipment and tools from the GEA Hilge assembly tool kit
•
Loctite Type 243
•
Klüber paste UH1 96-402
Fasten discharge casing
Coat tie bolts (0905.01) with Loctite type 243 and
screw in hand-tight (!) into the bearing housings or
motor stool.
Fig.62:
Tie bolts
Grease rear of the discharge casing (0107.00) with
Klüber paste.
Fig.63:
Discharge casing, rear
Push the discharge
casing (0107.00) over
the shaft (0211.00).
Fig.64:
Assembly screws for
CONTRA II
Fig.65:
Discharge casing and shaft
Use assembly screws when installing CONTRA II
so that the larger discharge casing (0107.00) of
CONTRA II is held in place. It will then not fall on
the shaft (0211.00) during assembly.
→ The discharge casing is fastened.