8.4
SIP
SIP stands for sterilisation in place, in which the pump is sterilised with
superheated steam. For steam sterilization or sanitization, minimum
temperatures of 121 ° C (250 ° F) must be applied to all wetted surfaces. The
maximum permissible temperatures can be obtained from the section technical
data.
The pump must not be in operation during steam sterilisation. A cool-down period
of at least one hour is required after the SIP process.
8.5
Manual exterior cleaning
Notice
Danger due to cleaning agents.
► Follow the manufacturer's instructions when using cleaning agents.
► Wear safety glasses and gloves.
► Dispose of cleaning agent properly.
► Do not use a high-pressure water jet to clean the pumps.
–
Regular manual external cleaning of the pump unit facilitates proper
operation.
–
Always check the impermeability of the motor (terminal box, condensation
water holes) before each cleaning.
–
Clean the outside of the pump with a soft cloth or brush and use warm water if
necessary.
–
When using a cleaning agent, make sure that it does not attack the surface of
the pump unit.
–
Remove dust and debris that may clog the fan and cooling fins of the engine.
–
Dry cleaning is preferable to wet cleaning.
–
The cleaning intervals depend on the degree of contamination.
Cleaning