Installation
Installing the motor on the hydraulic power unit
2007-9015-001
03-2014
5.7
Installing the motor on the hydraulic power unit
Warning!
Always shut off and lock the power supply before installing the
equipment.
Warning!
Always put back in place the safety guard before starting the
equipment.
Caution!
Always open 2 ball valves under the hydraulic power unit before
operating the equipment. Operating the hydraulic power unit with
closed ball valves will result in failure and/or injuries due to excess of
pressure in the oil filter.
Caution!
When electrical motors and/or control panels come from a supplier
other than the manufacturer, it is mandatory to verify components
compatibility. Make sure motors and/or control panels match the
equipment specifications. Refer to the Technical Data section on
Motor specifications and on Control panel specifications.
To tighten bolts adequately, refer to the Technical Data Section on Bolt
Torque Chart.
● Refer to pictures below to find the motor bolt pattern on the appropriate
motor support.
Motor
Motor support
Power
Type
Bolt pattern location
HP
KW
NEMA
IEC
A
5
3.7
184T
112
B
7.5
5.5
213T, 215T
132
● Wire the electrical motor to the control panel.
Attention!
It is mandatory to check motor rotation making sure it turns
in the direction indicated on the pump. Inverse rotation
may cause a major breakdown. To find the label position,
refer to the Appendix.