Mechanical Separation /
GEA Westfalia Separator
4.24 Alarm #37 - Max. speed monitoring (option)
MAX SPEED
MONITORING
during operation
Alarm#37 ENTER
Text display
Possible causes
Action
Actual speed higher than permitted
speed.
•
Check speed.
Speed setting for maximum speed too
low.
•
Check maximum speed setting.
Frequency not stable.
•
Check frequency.
Separator drive (50 or 60 Hz) does not
match frequency on site.
•
Check separator configuration for
the frequency with the frequency on
site.
Speed pickup defective.
•
Check speed pickup electrically;
replace if necessary.
•
Deselect function if required.
Note:
Alarm #37 only active when speed pickup is installed!
Help text – information on the control system
E N T E R
Step 1
Acknowledge fault
H E L P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
MAX SPEED
MONITORING
Please check:
Operating speed
->
Page 2
MAX SPEED
Setting
Frequency
Sep. configuration
->
Page 3
Frequency
Frequency on site
Speed pickup
back with ENTER
F 1