GEA Bock Plusbox SHG 34e/215-4 S P&P Series Скачать руководство пользователя страница 1

 D
 GB
 F
 E

1

96284-09.2016-DGbF

GEA Bock Plusbox

Assembly instructions

96284-09-2016-Gb

Translation of the original instructions

SHG(X)34e/215-4 (S)PB 

SHG(X)34e/215-4 (S)P&P

SHG(X)34e/255-4 (S)PB 

SHG(X)34e/255-4 (S)P&P

SHG(X)34e/315-4 (S)PB 

SHG(X)34e/315-4 (S)P&P

SHG(X)34e/380-4 (S)PB 

SHG(X)34e/380-4 (S)P&P

Содержание Bock Plusbox SHG 34e/215-4 S P&P Series

Страница 1: ...sembly instructions 96284 09 2016 Gb Translation of the original instructions SHG X 34e 215 4 S PB SHG X 34e 215 4 S P P SHG X 34e 255 4 S PB SHG X 34e 255 4 S P P SHG X 34e 315 4 S PB SHG X 34e 315 4...

Страница 2: ...ve the safety instructions contained in these instructions and in the compressor instructions These instructions must be passed onto the end customer along with the unit in which the Plusbox is instal...

Страница 3: ...4 6 1 Status Messages 6 2 Application Example 7 Maintenance 26 7 1 Preparation 7 2 Work to be carried out 8 Technical data 27 9 Dimensions and connections 28 10 Service 29 Note According to Commission...

Страница 4: ...omparable training which enablespersonneltoassemble install maintainandrepairrefrigeration and air conditioning systems Personnel must be capable of assessing the work to be carried out and recognisin...

Страница 5: ...rns and skin damage WARNING The Plusbox may not be used in potentially explosive environments These assembly instructions describe the standard version of the Plusbox named in the title manufac tured...

Страница 6: ...tion of its contents to others without express authorization is M Luftgek hlter Verfl ssigungssatz Air cooled condensing unit Aggregat Bezeichnung unit description Bestehend aus composed of Verdichter...

Страница 7: ...GX34e 315 4 P P AV38125A001 SHG 4 3 e 380 PB 4 S X 2 3 Type key example HG Hermetic Gas Cooled suction gas cooled X Ester oil charge 3 S Stronger motor 4 PB Plusbox P P Plug and Play Plusbox 4 Motor v...

Страница 8: ...y damp atmosphere or a combustible environment F E D C 1 2 3 INFO New compressors are factory filled with inert gas 3 bar nitrogen Leave this service charge in the compressor for as long as possible a...

Страница 9: ...t X3 Terminal strip terminal box Legend circuit diagram for Plusbox with accessories DANGER Risk of electric shock High voltage Only carry out work when the electrical system is discon nected from the...

Страница 10: ...T1 L1 T2 L2 T3 L3 QA1 EB1 PE EC1 3 M BT2 21 22 FC1 13 14 1 L1 2 T1 3 L2 4 T2 5 L3 6 T3 FC1 I I I 21 22 QA2 X1 1 2 4 5 6 7 10 11 12 13 8 3 X3 1 2 PE 9 1 2 FC2 L N B1 B2 12 14 11 OG OG X3 11 1 2 QA2 3...

Страница 11: ...F HP LP ex factory not connected 5 6 7 8 9 P Oil BP2 BP1 13 14 BT3 A1 A2 QA2 14 15 18 17 19 20 21 16 22 23 24 PE Duopress P T2 N L M S 1 2 3 4 PE PE 13 14 QA2 230V 5x1 0mm W3 1 2 4 3 PE 230V 5x1 0mm W...

Страница 12: ...0mm W6 230V 3x1 0mm W7 13 14 Freigabe Leistungsregler X1 PE 25 26 27 28 PE 29 30 1 X4 1 2 3 X5 1 2 3 1 2 PE PE 2 PE StSP1 N PE StSP2 4 1 Circuit diagram for Plusbox with accessories continuation Rele...

Страница 13: ...D GB F E 13 96284 09 2016 DGbF N PE 1 2 PE MA1 Kondensator l fter 1 M 0 230V 3x1 0mm W5 PE 1 2 31 32 PE 1 PE1 Geh useboden 1 PE2 Geh usedeckel PE PE housing cover housing base fan...

Страница 14: ...3 L3 QA1 EB1 PE EC1 3 M 91 96 92 97 93 98 95 99 12 18 19 54 BP3 1 2 Duopress P 11 14 QA2 21 22 FC1 13 14 L1 T1 L2 T2 L3 T3 FC1 I I I X1 1 2 4 5 6 7 10 11 12 13 14 15 8 3 400V 4x4 0mm W9 PE 1 2 3 0 400...

Страница 15: ...3 01 Relais1 03 02 T2 N L M S A1 A2 QA2 18 17 19 20 21 16 230V PE1 0mm W13 1 2 3 4 230V 3x1 0mm W14 2 1 230V 3x1 0mm W16 PE 1 2 22 23 24 25 26 PE PE 27 28 29 PE 230V 5x1 0mm W18 PE 04 Relais2 06 05 A1...

Страница 16: ...ng Set the fan speed controller according to the operating conditions of the plant Commissioning EFCe 5 1 Commissioning Plusbox without EFCe 5 2 Commissioning Plusbox with EFCe Note the enclosed Danfo...

Страница 17: ...compressor 5 Set the maximum continuous current and the nominal speed You can find the values on the nameplate of the compressor Please select language English AKD Wizard Select Application Compressor...

Страница 18: ...d 70 Hz 10 This setting depends on the application 9 Set the desired recycle time We recommend 3 minutes Does the application include a sine wave filter No Compressor Would you like to run AMA Recomme...

Страница 19: ...Sensor signal 4 20 mA 14 This connection is already pre wired by GEA 15 Check switch position below the user interface Compressor Attention Connect your 4 20 mA Signal as shown 13 54 Compressor Attent...

Страница 20: ...6 Set setpoint unit depends on the application 16 1 Select type of refrigerant 17 Set setpoint type Recommended setting Constant 18 Enter setpoint depends on the application Select Setpoint Unit C Com...

Страница 21: ...Setting ex factory No 22 Compressor setup completed 23 Go to main menu Compressor Compressor Setup Completed Do you wish to configure Pack Control No Compressor You now have the following options Go t...

Страница 22: ...me has elapsed 3 minutes Suction pressure is high enough No other parameters were change If other parameters were changed we recom mend to reset the EFCe to factory settings Afterwards have a look at...

Страница 23: ...ertain frequencies you have the option to skip them From the main menu Parameter 4 61 Bypass speed from Parameter 4 63 Bypass speed to 5 Commissioning 4 61 Bypass Speed from O Hz 0 0 Hz Speed Bypass 4...

Страница 24: ...nt limit W59 Imax reached Rotation speed of the compressor is not increased e g if suction pressure too high when compressor first commissioned 4 Auto Remote Standby No release by the inverter safety...

Страница 25: ...messages Display 0 2 1 0 1 2 2 6 3 3 22 28 Temp C 30 15 10 0 P P C P P Cut out LP switch Cut in LP switch Room temperatur Cut in HP switch Cut out HP switch Cut out VLT Cut in VLT and Min Setpoint Lim...

Страница 26: ...er fan and machine room and then remove again before subsequent start up Neither dirt nor moisture are allowed to penetrate the machine room We recommend using compressed air and a soft brush for clea...

Страница 27: ...80 18 3 10 5 2 60 600 7895 8 0 1 2 1 1 8 47 201 SHG34e 255 4 P P 22 10 17 0 9 8 2 60 600 7895 8 0 1 2 1 1 8 47 195 SHG34e 255 4 S P P 22 10 21 1 12 2 2 60 600 7895 8 0 1 2 1 1 8 47 200 SHG34e 315 4 P...

Страница 28: ...Drawing no 3 2 Part No Ma stab 0 1 ber above Freigabe Approved z y Allgemeintoleranzen General tolerances Drawing No bis up to x w u t s Kund DIN ISO 2768 mK Ra Rz Ersat Dimension Passung Clearance B...

Страница 29: ...UNF SHG34e 380 4 S PB 35 13 8 16 5 8 1 2 NPTF 7 16 UNF 7 16 UNF 7 16 UNF SV Suction line shut off valve FLA Liquid outlet SI Connection safety valve Y1 Connection liquid side lockable Y2 Connection l...

Страница 30: ...sen Germany Phone 49 0 7022 9454 0 Fax 49 0 7022 9454 137 info gea com gea com GEA Group is a global engineering company with multi billion euro sales and operations in more than 50 countries Founded...

Отзывы: