Description
Structure and functions
7159-9001-108
01. February 2020
3.1.1
Functional sequence (AutoSelect 3000 / AutoSelect 3000 HD)
Notes
● All animals which are to be segregated will be fitted with a
responder/Rescounter according to the design in each case and will be
identified by the identification frame.
● AutoSelect 3000 SA:
Only the animals to be segregated are given a label.
Animal segregation initial position
● No animal in identification
EG
SG
ID
3
1
2
2
EG
Entrance gate
SG
Segregation gate
ID
Identification frame
Example:
Leg identification
1-3
Light scanner
B1-B3
- Entrance gate open
- Segregation gate(s) closed
- B1-B3: Light scanner free
- Identification is constantly active
Setting: DPService 010/000/009
Animal enters animal segregation
● Animal goes through the entrance gate
● animal identification (ID)
EG
SG
ID
3
1
2
2
ID-A: Animal is not identified (no label)
- Segregation path unchanged
ID-B: Animal is identified
- Responder code is sent to DairyPlan
- DairyPlan sends the segregation path corresponding to the animal
● B1: Light scanner identifies the animal in the identification area
● Entrance gate closes if segregation path A or B is specified
EG
SG
ID
3
1
2
2
● The light scanners are checked (B1, B2, B3)
A distinction is made between the following cases:
- 1 animal in the segregation area
- 2 animals in the segregation area