![GEA Aseptomag ADV Скачать руководство пользователя страница 53](http://html2.mh-extra.com/html/gea/aseptomag-adv/aseptomag-adv_operating-instruction_5081487053.webp)
•
Vice
Preparing disassembly
Carry out the following steps:
1.
Bring the actuator to the non-actuated position.
2.
Remove the feedback unit.
3.
Fasten assembly tool "clamping piece" on the rear of the actuator.
Fig.54:
Attaching clamping piece
4.
Grip the actuator in the vice using the clamping piece.
Fig.55:
Clamping the actuator
®
Disassembly has been prepared
Removing assembly spring
Carry out the following steps:
1.
Turn the actuator base counter-clockwise using a flexible head spanner, see
illustration.
!
Rotate the actuator base until the assembly spring begins to move out of the
slot in the cylinder.
Maintenance
Disassembling and Assembling Actuator PA80 - PA255