![GEA Aseptomag ADV Скачать руководство пользователя страница 52](http://html2.mh-extra.com/html/gea/aseptomag-adv/aseptomag-adv_operating-instruction_5081487052.webp)
Fig.52:
Secure internal assembly
4.
Apply max. 3 bar of compressed air to the pressurizing tool.
!
Air pressures > 3 bar can damage the metal bellows.
5.
Immerse the internal assembly in a water bath for approx. 30 seconds.
!
While the internal assembly is immersed, check the internal assembly for
leaks. Leakages will be indicated by air bubbles appearing on the surface.
Fig.53:
Water bath
6.
Remove the internal assembly from the pressurizing tool in reverse order.
®
This completes the leak test.
10.11
Disassembling and Assembling Actuator PA80 - PA255
10.11.1 Disassembling Actuator PA80 - PA255
Tools required:
•
Flexible head spanner
•
Assembly tool clamping piece
•
Assembly tool for spring assembly
•
Assembly tool for O-ring
Maintenance
Disassembling and Assembling Actuator PA80 - PA255
430BAL012841EN_1
52
07.03.2018
Содержание Aseptomag ADV