Advance Planning

INSTALLATION CLEARANCES

These vent hoods are designed to be installed onto a
wall or beneath a soffit or cabinet.
• Install these hoods* 30" Min. to 36" Max. above the

cooking surface.

*These hoods may be installed 24" min. above a gas or

electric drop-in style cooktop. Always observe the 30"
to 36" clearance when installed over any professional
style cooktop or range.

OPTIONAL DUCT COVER
ACCESSORIES

Decorative duct covers are available in 6" and 12"
heights. Duct covers may be stacked, in various
combinations, to conceal the ductwork running from
the top of the hood to the ceiling.
• Before you begin, you should determine the installa-

tion height of the hood and order the correct size
duct cover.  The duct covers should be ordered at the
same time as the vent hood and be on site before
installation. Order the duct cover corresponding to
your model.

In this installation the ductwork running from the top
of the hood will be concealed in the soffit or upper
cabinetry.

For this installation, a decorative duct cover is avail-
able to conceal the ductwork running from the top of
the hood. Use of the duct cover requires special
consideration to the installation height above the
countertop.

6" Duct  Covers
Hood Model

6” Duct Cover

Dimensions

ZV48T, ZV48S

ZX48DC6

6"H x 19-11/16"W x 11-7/8"D

ZV36T, ZV36S

ZX36DC6

6"H x 15-3/4"W x 11-7/8"D

ZV30T, ZV30S

ZX36DC6

6"H x 15-3/4"W x 11-7/8"D

12" Duct Covers

Hood Model

12” Duct Cover

Dimensions

ZV48T, ZV48S

ZX48DC12

12"H x 19-11/16"W x 11-7/8"D

ZV36T, ZV36S

ZX36DC12

12"H x 15-3/4"W x 11-7/8"D

ZV30T, ZV30S

ZX36DC12

12"H x 15-3/4"W x 11-7/8"D

6" Duct Cover

12" Duct Cover

Note: 

Clearances may vary due to type of cooking product and

local codes. Check with local inspectors to be sure standard is
applicable.

SOFFIT

Soffit Installation

30" MIN.

36" MAX.

Wall Mount Installation

30" MIN.

36" MAX.

Содержание ZV48T

Страница 1: ...bring good things to life If you have questions call 800 GE CARES or visit our website at www monogram com Installation Instructions 30 36 and 48 Professional Vent Hoods Models ZV48T ZV48S ZV36T ZV36...

Страница 2: ...in accordance with National Electrical Code ANSI NFPA 70 1990 or latest edition CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spac...

Страница 3: ...5 Duct Fittings 6 Using Duct Cover Accessories 7 Tools and Materials Required 8 Remove the packaging 8 Parts Provided 9 Step 1 Determine Ductwork and Wiring Locations 10 Step 2A Install Hood Onto Wal...

Страница 4: ...r the duct cover corresponding to your model In this installation the ductwork running from the top of the hood will be concealed in the soffit or upper cabinetry For this installation a decorative du...

Страница 5: ...soffit Stack one or more duct covers over the top of the hood to reach your ceiling height POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GRO...

Страница 6: ...ucting is used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as possible Do NOT use flexible plastic ducting...

Страница 7: ...inal framing and wall finishing This will help to accurately locate studs ductwork and electrical service Read these examples carefully to determine the need for one or more 6 or 12 duct covers A B C...

Страница 8: ...ing support to the back of the hood Remove and set aside the mounting support with screws for later installation DO NOT DISCARD Remove tape and packing material from the hood and all supplied parts To...

Страница 9: ...DWARE PACKAGE Locate and check contents Screws shown actual size 6 Screws to secure hood to the wood support 2 secured to wood support Torx 20 4 screws to secure the transition to the hood outlet on t...

Страница 10: ...GH REAR WALL Measure the supplied duct transition with any straight run length of duct used plus 90 elbow height Draw horizontal line on the wall intersecting the centerline House Wiring Location The...

Страница 11: ...he wood support IMPORTANT Remove shipping tape from damper and check that damper moves freely Duct Transition Top of Hood SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET GO TO STEP 2B Locate...

Страница 12: ...in the top view illustration Install Transition Onto Top of Hood Place the transition piece over the hood exhaust and secure with 4 screws provided Use duct tape to seal the connection Check to be sur...

Страница 13: ...ed with the covers Verify that power is turned off at the source WARNING If house wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be su...

Страница 14: ...lock washer Screw is marked with red paint Plug connector into the motor IMPORTANT Connector ends are designed to mate only one way Match flat and round connectors as shown Spring Clip Outlet Attachm...

Страница 15: ...stand offs with the screw hole towards the inside of the hood Secure the rod to the stand offs with the supplied Allen wrench Follow the same procedure on the opposite side Screw Stand offs Into Hood...

Страница 16: ...ur area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice Pub No 49 80151...

Отзывы: