![GE UR T60 Скачать руководство пользователя страница 515](http://html.mh-extra.com/html/ge/ur-t60/ur-t60_instruction-manual_130388515.webp)
GE Multilin
T60 Transformer Protection System
A-1
APPENDIX A
A.1 PARAMETER LISTS
A
Appendices
APPENDIX A FlexAnalog and FlexInteger ParametersA.1Parameter Lists
A.1.1 FLEXANALOG ITEMS
A FlexAnalog parameter is an analog parameter.
FlexAnalog items are also viewable in a web browser. Enter the IP address of the UR, access the
Device Information
Menu
option, then the
FlexAnalog Parameter Listing
option. Entries displayed online depend on order code.
Table A–1: FLEXANALOG DATA ITEMS (Sheet 1 of 24)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
5792
RGF 1 Igd Mag
Amps
Restricted ground fault 1 differential ground current magnitude
5794
RGF 1 Igr Mag
Amps
Restricted ground fault 1 restricted ground current magnitude
5796
RGF 2 Igd Mag
Amps
Restricted ground fault 2 differential ground current magnitude
5798
RGF 2 Igr Mag
Amps
Restricted ground fault 2 restricted ground current magnitude
5800
RGF 3 Igd Mag
Amps
Restricted ground fault 3 differential ground current magnitude
5802
RGF 3 Igr Mag
Amps
Restricted ground fault 3 restricted ground current magnitude
5804
RGF 4 Igd Mag
Amps
Restricted ground fault 4 differential ground current magnitude
5806
RGF 4 Igr Mag
Amps
Restricted ground fault 4 restricted ground current magnitude
5808
RGF 5 Igd Mag
Amps
Restricted ground fault 5 differential ground current magnitude
5810
RGF 5 Igr Mag
Amps
Restricted ground fault 5 restricted ground current magnitude
5812
RGF 6 Igd Mag
Amps
Restricted ground fault 6 differential ground current magnitude
5814
RGF 6 Igr Mag
Amps
Restricted ground fault 6 restricted ground current magnitude
6144
SRC 1 Ia RMS
Amps
Source 1 phase A current RMS
6146
SRC 1 Ib RMS
Amps
Source 1 phase B current RMS
6148
SRC 1 Ic RMS
Amps
Source 1 phase C current RMS
6150
SRC 1 In RMS
Amps
Source 1 neutral current RMS
6152
SRC 1 Ia Mag
Amps
Source 1 phase A current magnitude
6154
SRC 1 Ia Angle
Degrees
Source 1 phase A current angle
6155
SRC 1 Ib Mag
Amps
Source 1 phase B current magnitude
6157
SRC 1 Ib Angle
Degrees
Source 1 phase B current angle
6158
SRC 1 Ic Mag
Amps
Source 1 phase C current magnitude
6160
SRC 1 Ic Angle
Degrees
Source 1 phase C current angle
6161
SRC 1 In Mag
Amps
Source 1 neutral current magnitude
6163
SRC 1 In Angle
Degrees
Source 1 neutral current angle
6164
SRC 1 Ig RMS
Amps
Source 1 ground current RMS
6166
SRC 1 Ig Mag
Amps
Source 1 ground current magnitude
6168
SRC 1 Ig Angle
Degrees
Source 1 ground current angle
6169
SRC 1 I_0 Mag
Amps
Source 1 zero-sequence current magnitude
6171
SRC 1 I_0 Angle
Degrees
Source 1 zero-sequence current angle
6172
SRC 1 I_1 Mag
Amps
Source 1 positive-sequence current magnitude
6174
SRC 1 I_1 Angle
Degrees
Source 1 positive-sequence current angle
6175
SRC 1 I_2 Mag
Amps
Source 1 negative-sequence current magnitude
6177
SRC 1 I_2 Angle
Degrees
Source 1 negative-sequence current angle
6178
SRC 1 Igd Mag
Amps
Source 1 differential ground current magnitude
6180
SRC 1 Igd Angle
Degrees
Source 1 differential ground current angle
6208
SRC 2 Ia RMS
Amps
Source 2 phase A current RMS
6210
SRC 2 Ib RMS
Amps
Source 2 phase B current RMS
6212
SRC 2 Ic RMS
Amps
Source 2 phase C current RMS
6214
SRC 2 In RMS
Amps
Source 2 neutral current RMS
6216
SRC 2 Ia Mag
Amps
Source 2 phase A current magnitude
6218
SRC 2 Ia Angle
Degrees
Source 2 phase A current angle
Содержание UR T60
Страница 10: ...x T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 14: ...xiv T60 Transformer Protection System GE Multilin 0 1 BATTERY DISPOSAL 0 BATTERY DISPOSAL 0 ...
Страница 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 436: ...5 298 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 492: ...8 18 T60 Transformer Protection System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 510: ...9 18 T60 Transformer Protection System GE Multilin 9 6 COMMISSIONING TEST TABLES 9 COMMISSIONING 9 ...
Страница 678: ...C 30 T60 Transformer Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 688: ...D 10 T60 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Страница 700: ...E 12 T60 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...