28
UR Family Software 5.80 - Release Notes
Software
Software 5.80
N The new “Simplified GOOSE Configurator” reduces number of steps required for configuring IEC61850
GOOSE messages
Applicable: UR Setup, UR Engineer
Description: A new software tool named “Simplified GOOSE Configurator” has been added to the UR Setup
and UR Engineer software. This routine gives users a seamless way to configure IEC61850 GOOSE
messages.
The configurator requires settings files to be located in a new “GOOSE site” that can be created within the
offline window. Users can drag any of the existing relay logic-operands from the relays at the “GOOSE
Site” (publisher) and drop them into any of the other devices (subscriber). All the UR internal operands are
supported (digital, analogs, integers).
This tool also supports a column for Generic IEDs that allows for easy configuration of GOOSE publishing
only, this intended for those GOOSE messages which subscribers are not UR devices.
Once the operands have been dragged and dropped, the Configurator automatically updates the relay
(both publisher and subscriber) setting files by configuring the required fields (remote devices, GOOSE data
sets and data Items, remote inputs, Generic logical nodes).
This software tool reduces the number of steps required for IEC61850 GOOSE configuration and enables
customers with limited communication experience to set their GOOSE messages.
GE Tracking Number: 580-24
N New “Backup / Restore” modes for UR Setup software environment file
Applicable: UR Setup, UR Engineer
Description: A new software tool named “Environment Backup” mode has been added to the UR Setup
and UR Engineer software.
The environment file contains information on the Online and Offline windows, so in the cases of moving or
damaged computer, customers can easily restore their UR Setup Software configuration by reading the
file.
The backup file can be created and read from the File menu.
GE Tracking Number: 580-25
N UR Setup Offline windows to support setting file “Sites”
Applicable: UR Setup, UR Engineer
Description: A new feature in the UR Setup and UR Engineer software enables users to group settings file
into settings “Sites”.
“Setting sites” can be created in the Offline window area, and like the “Device Sites,” are used to organize
settings files into different groups as per customer needs (location, application, order-code, and so on).
GE Tracking Number: 580-26
N New software tool allows users to shift among supported languages and front panel types
Applicable: UR Setup, UR Engineer
Description: A new maintenance feature in the UR Setup and UR Engineer software enables users to
change the relay language and upgrade the type of front panel that the relay has.
The supported languages are: English, French, Russian, and Chinese.
The supported front panels are: Basic, Basic with Push-buttons, Enhanced and Enhanced with push-