GE Multilin
C70 Capacitor Bank Protection and Control System
B-39
APPENDIX B
B.4 MEMORY MAPPING
B
9C9A
Automatic voltage regulator 1 var level to open
–1.500 to 1.500
pu
0.001
F002
1050
9C9B
Automatic voltage regulator 1 power factor limit
0.50 to 1.00
---
0.01
F001
100
9C9C
Automatic voltage regulator 1 var open mode
0 to 1
---
1
F537
1 (Minimize no. of ops.)
9C9D
Automatic voltage regulator 1 delay before close
0 to 65.535
s
0.001
F001
1000
9C9E
Automatic voltage regulator 1 delay before open
0 to 65.535
s
0.001
F001
1000
9C9F
Automatic voltage regulator 1 block
0 to 65.535
---
1
F300
0
9CA0
Automatic voltage regulator 1 events
0 to 1
---
1
F102
0 (Disabled)
9CA1
Automatic voltage regulator 1 target
0 to 2
---
1
F109
0 (Self-Reset)
9CA2
Automatic voltage regulator 1 reserved
---
---
---
---
---
9CA3
...Repeated for automatic voltage regulator 2
9CB6
...Repeated for automatic voltage regulator 3
Neutral current unbalance settings (read/write, 3 modules)
9CE0
Neutral current unbalance 1 function
0 to 1
---
1
F102
0 (Disabled)
9CE1
Neutral current unbalance 1 bank source
0 to 5
---
1
F167
0 (SRC 1)
9CE2
Neutral current unbalance 1
k
magnitude
0 to 0.1500
---
0.0001
F001
0
9CE3
Neutral current unbalance 1
k
angle
0 to 359
°
1
F001
0
9CE4
Neutral current unbalance 1 stage 1 pickup
0 to 5.000
pu
0.001
F001
20
9CE5
Neutral current unbalance 1 stage 1 slope
0 to 10.0
%
0.1
F001
20
9CE6
Neutral current unbalance 1 stage 2 pickup
0 to 5.000
pu
0.001
F001
30
9CE7
Neutral current unbalance 1 stage 2 slope
0 to 10.0
%
0.1
F001
20
9CE8
Neutral current unbalance 1 stage 3 pickup
0 to 5.000
pu
0.001
F001
40
9CE9
Neutral current unbalance 1 stage 3 slope
0 to 10.0
%
0.1
F001
20
9CEA
Neutral current unbalance 1 stage 4 pickup
0 to 5.000
pu
0.001
F001
50
9CEB
Neutral current unbalance 1 stage 4 slope
0 to 10.0
%
0.1
F001
50
9CEC
Neutral current unbalance 1 stage 1 pickup delay
0 to 600.00
s
0.01
F001
3000
9CED
Neutral current unbalance 1 stage 2 pickup delay
0 to 600.00
s
0.01
F001
1000
9CEE
Neutral current unbalance 1 stage 3 pickup delay
0 to 600.00
s
0.01
F001
100
9CEF
Neutral current unbalance 1 stage 4 pickup delay
0 to 600.00
s
0.01
F001
20
9CF0
Neutral current unbalance 1 dropout delay
0 to 600.00
s
0.01
F001
25
9CF1
Neutral current unbalance 1 stage 1 block
0 to 65.535
---
1
F300
0
9CF2
Neutral current unbalance 1 stage 2 block
0 to 65.535
---
1
F300
0
9CF3
Neutral current unbalance 1 stage 3 block
0 to 65.535
---
1
F300
0
9CF4
Neutral current unbalance 1 stage 4 block
0 to 65.535
---
1
F300
0
9CF5
Neutral current unbalance 1 target
0 to 2
---
1
F109
0 (Self-Reset)
9CF6
Neutral current unbalance 1 events
0 to 1
---
1
F102
0 (Disabled)
9CF7
...Repeated for neutral current unbalance 2
9D0E
...Repeated for neutral current unbalance 3
Neutral voltage unbalance settings (read/write, 3 modules)
9D50
Neutral voltage unbalance 1 function
0 to 1
---
1
F102
0 (Disabled)
9D51
Neutral voltage unbalance 1 bank source
0 to 5
---
1
F167
0 (SRC 1)
9D52
Neutral voltage unbalance 1 bus source
0 to 5
---
1
F167
0 (SRC 1)
9D53
Neutral voltage unbalance 1 bus 3V0
0 to 1
---
1
F241
0 (Calculated)
9D54
Neutral voltage unbalance 1 ground
0 to 1
---
1
F255
0 (VT (ungrnd))
9D55
Neutral voltage unbalance 1 AB ratio
0.7500 to 1.2500
---
0.0001
F001
10000
9D56
Neutral voltage unbalance 1 AC ratio
0.7500 to 1.2500
---
0.0001
F001
10000
9D57
Neutral voltage unbalance 1 stage 1 pickup
0.001 to 1.000
pu
0.001
F001
10
9D58
Neutral voltage unbalance 1 stage 1 slope
0 to 10.0
%
0.1
F001
0
9D59
Neutral voltage unbalance 1 stage 2 pickup
0.001 to 1.000
pu
0.001
F001
20
9D5A
Neutral voltage unbalance 1 stage 2 slope
0 to 10.0
%
0.1
F001
0
9D5B
Neutral voltage unbalance 1 stage 3 pickup
0.001 to 1.000
pu
0.001
F001
20
9D5C
Neutral voltage unbalance 1 stage 3 slope
0 to 10.0
%
0.1
F001
50
9D5D
Neutral voltage unbalance 1 stage 4 pickup
0.001 to 1.000
pu
0.001
F001
30
9D5E
Neutral voltage unbalance 1 stage 4 slope
0 to 10.0
%
0.1
F001
30
9D5F
Neutral voltage unbalance 1 stage 1 pickup delay
0 to 600.00
s
0.01
F001
3000
Table B–9: MODBUS MEMORY MAP (Sheet 32 of 53)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание UR Series C70
Страница 2: ......
Страница 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 C70 Capacitor Bank Protection and Control System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 124: ...4 30 C70 Capacitor Bank Protection and Control System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 344: ...5 220 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 396: ...8 18 C70 Capacitor Bank Protection and Control System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 414: ...9 18 C70 Capacitor Bank Protection and Control System GE Multilin 9 1 OVERVIEW 9 THEORY OF OPERATION 9 ...
Страница 436: ...10 22 C70 Capacitor Bank Protection and Control System GE Multilin 10 4 SETTING EXAMPLE 10 APPLICATION OF SETTINGS 10 ...
Страница 547: ...GE Multilin C70 Capacitor Bank Protection and Control System B 79 APPENDIX B B 4 MEMORY MAPPING B ...
Страница 548: ...B 80 C70 Capacitor Bank Protection and Control System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Страница 586: ...D 10 C70 Capacitor Bank Protection and Control System GE Multilin D 1 OVERVIEW APPENDIXD D ...
Страница 598: ...E 12 C70 Capacitor Bank Protection and Control System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...