GE Multilin
C70 Capacitor Bank Protection and Control System
6-3
6 ACTUAL VALUES
6.2 STATUS
6
6.2STATUS
For status reporting, ‘On’ represents Logic 1 and ‘Off’ represents Logic 0.
6.2.1 CONTACT INPUTS
PATH: ACTUAL VALUES
Ö
STATUS
Ö
CONTACT INPUTS
The present status of the contact inputs is shown here. The first line of a message display indicates the ID of the contact
input. For example, ‘Cont Ip 1’ refers to the contact input in terms of the default name-array index. The second line of the
display indicates the logic state of the contact input.
6.2.2 VIRTUAL INPUTS
PATH: ACTUAL VALUES
Ö
STATUS
ÖØ
VIRTUAL INPUTS
The present status of the 64 virtual inputs is shown here. The first line of a message display indicates the ID of the virtual
input. For example, ‘Virt Ip 1’ refers to the virtual input in terms of the default name. The second line of the display indicates
the logic state of the virtual input.
6.2.3 REMOTE INPUTS
PATH: ACTUAL VALUES
Ö
STATUS
ÖØ
REMOTE INPUTS
The present state of the 32 remote inputs is shown here.
The state displayed will be that of the remote point unless the remote device has been established to be “Offline” in which
case the value shown is the programmed default state for the remote input.
CONTACT INPUTS
Cont Ip 1
Off
Range: On, Off
MESSAGE
Cont Ip 2
Off
Range: On, Off
↓
MESSAGE
Cont Ip xx
Off
Range: On, Off
VIRTUAL INPUTS
Virt Ip 1
Off
Range: On, Off
MESSAGE
Virt Ip 2
Off
Range: On, Off
↓
MESSAGE
Virt Ip 64
Off
Range: On, Off
REMOTE INPUTS
REMOTE INPUT 1
STATUS: Off
Range: On, Off
MESSAGE
REMOTE INPUT 2
STATUS: Off
Range: On, Off
↓
MESSAGE
REMOTE INPUT 32
STATUS: Off
Range: On, Off
NOTE
Содержание UR Series C70
Страница 2: ......
Страница 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 C70 Capacitor Bank Protection and Control System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 124: ...4 30 C70 Capacitor Bank Protection and Control System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 344: ...5 220 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 396: ...8 18 C70 Capacitor Bank Protection and Control System GE Multilin 8 3 ENERVISTA SECURITY MANAGEMENT SYSTEM 8 SECURITY 8 ...
Страница 414: ...9 18 C70 Capacitor Bank Protection and Control System GE Multilin 9 1 OVERVIEW 9 THEORY OF OPERATION 9 ...
Страница 436: ...10 22 C70 Capacitor Bank Protection and Control System GE Multilin 10 4 SETTING EXAMPLE 10 APPLICATION OF SETTINGS 10 ...
Страница 547: ...GE Multilin C70 Capacitor Bank Protection and Control System B 79 APPENDIX B B 4 MEMORY MAPPING B ...
Страница 548: ...B 80 C70 Capacitor Bank Protection and Control System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Страница 586: ...D 10 C70 Capacitor Bank Protection and Control System GE Multilin D 1 OVERVIEW APPENDIXD D ...
Страница 598: ...E 12 C70 Capacitor Bank Protection and Control System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...