LED Lighting System
Symptom
Solution
All letters are OFF
• Check AC input connetion and/or check circuit breaker.
• Check wire connection(s) at the Tetra
®
LED System and power supply for improper
termination(s) or short circuits. Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the
power supply and the white wire (-) of the LED strip to the black wire (-) of the power supply.
Some LEDs appear dim
• Ensure the overall length of the Tetra
®
LED System does not exceed the maximum load.
• Ensure the length of supply wire is equal to or below the recommended remote mounting
distance.
Some of the letters are
not illuminated
• Check wire connection(s) at the Tetra
®
LED System and power supply for improper
termination(s) or short circuits. Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the
power supply and the white wire (-) of the LED strip to the black wire (-) of the power supply.
Shadows
• Re-route supply wire and secure to the back of the can with silicone. Adjust wire
connector orientation so that it does not cover any LEDs.
• Adjust LED layout to ensure uniformity of illumination on the face of the letter.
Troubleshooting
SIGN055-R082409
(GEWHMMS5, GEWWMMS5, GERDMMS5, GEGLMMS5, GEBLMMS5)
RISK OF ELECTRIC SHOCK:
• Turn power OFF before inspection, installation
or removal.
• Properly ground Tetra Power Supply enclosure.
RISK OF FIRE:
• Follow all NEC and local codes.
• Use only UL approved wire for input/output
connections. Minimum size 18 AWG (0.82 mm
2
)
WARNING!
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Prepare Electrical Wiring
Electrical Requirements
• Do not use in wet locations.
• The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
Risk of electrical shock. Disconnect power before servicing or
installing product.
Risque de choc électrique. Couper l’alimentation avant
le dépannage ou avant l’installation du produit.
WARNING / AVERTISSMENT
6180 Halle Drive • Valley View, Ohio 44125-4635 • USA
P: 216.606.6555 • F: 216.606.6599 • www.lumination.com • [email protected]
Lumination, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of Lumination, LLC. The GE brand, logo, and ecomagination are trademarks of the General Electric Company.
© 2009 Lumination, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
For customer service & technical support, contact:
1-888-MY-GE-LED (1.888.694.3533)
Tips
• Tetra LED systems are rated for damp location use by UL, and should be protected from direct exposure to moisture
(i.e., rain & snow).
• For optimal light uniformity in halo-lit applications the Tetra LED modules should be mounted on UL recognized plastic
and the light output from the Tetra LED system should be directed back into the sign enclosure. This will allow for
uniform backlighting of the sign and will provide simple mounting for the Tetra LED system.
• When mounting LED modules for halo-lit applications the clear acrylic should be recessed into the body of the sign or
a bead of silicone should be applied to provide a barrier against the elements.
• A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of
the letter to keep water from collecting on the Tetra LED strip.
IP66 rated: separate enclosure required for outdoor use, UL damp location rated
Conforms to the following standards: