Installation Guide

SIGN175 | GE2024-1638

Tetra

®

 miniMAX MS

LED Lighting System

GEMS71-1, GEMS50-1, GEMS41-1, GEMS32-1, 

GEMSRD-1, GEMSBL-1, GEMSGL-1

RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN 

ACCORDANCE WITH KIT INSTRUCTIONS.

KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY 

THE INSTRUCTIONS ARE PRESENT.

TROUSSE DE CONVERSION À DEL POUR LA 

MODERNISATION DES ENSEIGNES

À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.

Save These Instructions

Use only in the manner intended by the manufacturer. If you 

have any questions, contact the manufacturer.

12

Volt

For the latest North American install guides for your product go to: https://products.gecurrent.com/led-signage-lighting 

For the latest European install guides for your product go to: https://products.gecurrent.com/eu

BG

 

Българската версия на инструкциите за инсталаця 
и информация за безопасност могат да бъдат 
намерени на следния адрес: https://products.
gecurrent.com/eu

CS

 

Návod k montáží a bezpečnostní informace v češtině 
najdete zde: https://products.gecurrent.com/eu

DA

 

Den danske version af installationsvejledningen 
og sikkerhedsoplysninger kan findes på følgende 
placering: https://products.gecurrent.com/eu

DE

 

Die deutsche Version der Installationsanleitung und 
Sicherheitsinformationen finden Sie in folgendem 
Verzeic: https://products.gecurrent.com/eu

EL

  Μπορείτε να βρείτε την ελληνική εκδχή των  οδηγιών   

νγκατάστασης και των πληροφοριών ασφάλειας στην 
εξής τοποθεσία: https://products.gecurrent.com/eu

ES

 

La versión española de las instrucciones de instalación 
y la información sobre seguridad puede encontrarse 
en la siguiente ubicación: https://products.gecurrent.
com/eu

ET

 

Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate 
aadressilt: https://products.gecurrent.com/eu

FI

 

Asennusohjeiden ja turvallisuustietojen 
suomenkielinen versio löytyy seuraavasta paikasta: 
https://products.gecurrent.com/eu

FR

 

La version française des instructions d’installations 
et information de sécurité est disponible à l’adresse 
suivante: https://products.gecurrent.com/eu

HR

 

Hrvatska verzija priručnika za ugradnju i sigurnosnih 
informacija nalazi se na sljedečoj lokaciji: https://
products.gecurrent.com/eu

HU

 

A telepítési útmutató és a biztnosági információk 
magyar nyelvű változata az alábbi címen található: 
https://products.gecurrent.com/eu

IT

 

La versione italiana del manuale di installazione e 
sicurezza può essere reperita nella seguente sezione: 
https://products.gecurrent.com/eu

LT

 

Lietuvišką diegimo instrukcijos ir saugos informacijos 
versiją galima rasti šioje vietoje: https://products.
gecurrent.com/eu

LV

 

Uzstādīšanas instrukciju un drošības informāciju 
latviešu valodā var atrast šeit: https://products.
gecurrent.com/eu

NL

 

De Nederlandse versie van de installatie-instructies 
en veiligheidsinformatie kan op de volgende locatie 
worden gevonden: https://products.gecurrent.com/eu

PL

 

Polską wersję instrukcji instalacji oraz informacje 
dotyczące bezpieczeństwa można znaleźć w 
następującej lokalizacji: https://products.gecurrent.
com/eu

PT

  A versão em Português das instruções de instalação e 

das informações de segurança pode ser encontrada 
na seguinte localização: https://products.gecurrent.
com/eu

RO

  Versiunea în limba română a instrucţiunilor de 

instalare şi a informaţiilor de siguranţă pot fi găsite la: 
https://products.gecurrent.com/eu

SV

  Ni hittar den svenska versionen av 

installationsanvisningarna och säkerhetsinformationen 
på följande plats: https://products.gecurrent.com/eu

SL

  Previdnostna opozorila in varnostne informacije so na 

zadnji strani vodnika za namestitev. Pred začetkom 
namestitve izdelka jih skrbno preberite: https://
products.gecurrent.com/eu

SK

  Slovenskú verziu montažnej príručky a 

bezpečnostn

ŷ

ch instrukcií nájdete na nasledujúcej 

lokalite: https://products.gecurrent.com/eu

EN

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Prepare Electrical Wiring 

Electrical Requirements

•  Limited to use in dry and damp locations. The suitability of rain 

enclosures shall be determined if intended for wet location.

•  The grounding and bonding of the LED Driver shall be done in 

accordance with National Electric Code (NEC) Article 600.

•  Follow all National Electric Codes (NEC) and local codes.

•  These products are only suitable for connection to a circuit from 

a Class 2 power source.

•  These products have not been evaluated for use when 

connected to a power source that does not comply with Class 2 

voltage and energy limited supplies.

FOR UL ONLY

Содержание Tetra miniMAX MS GEMS71-1

Страница 1: ...iji https products gecurrent com eu HU A telepítési útmutató és a biztnosági információk magyar nyelvű változata az alábbi címen található https products gecurrent com eu IT La versione italiana del manuale di installazione e sicurezza può essere reperita nella seguente sezione https products gecurrent com eu LT Lietuvišką diegimo instrukcijos ir saugos informacijos versiją galima rasti šioje viet...

Страница 2: ...OU DE CHOC ÉLECTRIQUE L installation de l équipement de remplacement DEL exige Ia connaissance des systèmes électriques pour enseignes Si non qualifié ne tentez pas d installation Veuillez contacter un électricien qualifié Risque d incendie ou de choc électrique Installez cet ensemble seulement dans des enseignes hôtes qui ont été identifiés dans les instructions d installation et dont la capacité...

Страница 3: ... 2 08 mm2 wire connectors or 22 18 AWG 0 33 0 82 mm2 in line IDC connectors 6 or 8 M3 or M4 screws 1 8 inch 3 2 mm rivets or electronic grade silicone or equivalent Tetra 12 Volt Power Supply Tetra miniMAX MS LED modules Components Layout Modules Drill a 1 4 inch 6 4 mm hole near the LED strip and grommet the hole for supply wire access Clean and remove all debris from the inside of the channel le...

Страница 4: ...val of the existing lighting equipment eliminates the disconnect switch as required by applicable local state or country electrical codes a new disconnect switch must be installed 4 Existing Signs Only Repair and seal any unused openings in the electrical enclosure Openings greater than 12 7 mm 1 2 in diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk S...

Страница 5: ...les 60 ft 18 29 m 150 modules 60 ft 18 29 m per output channel 450 modules 180 ft 54 88 m per power supply GEMSGL 1 12VDC 26mA module 0 312W module 18 AWG 0 82 mm2 Supply Wire 16 AWG 1 31 mm2 Supply Wire 14 AWG 2 08 mm2 Supply Wire 12 AWG 3 31 mm2 Supply Wire 20W Power Supply 120 ft 36 6 m 60W Power Supply 30 ft 9 1 m 50 ft 15 2 m 80 ft 24 4 m 120 ft 36 6 m 180W Power Supply 30 ft 9 1 m 50 ft 15 2...