imagination at work
Power Supply Features
(GEPS12-180U)
• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX,
Tetra PowerStrip and Tetra miniStrip lighting systems
• Class 2 wiring per NEC Article 725 (SELV equivalent)
• Damp location rated
• IP66 rated: separate enclosure required
• Three 60 watt output banks
Tetra
®
LED Systems Power Supply
GE
Lighting Solutions
Installation Guide
12
Volt
Connect the supply wire that is
attached to the Tetra LED System to
the red (+) and black (-) output wires
of the power supply as outlined in
the “
Electrical Connections
” section
of your LED system’s Installation
Instructions.
NOTE:
Three 60 watt output banks per
power supply. Do not interconnect
output terminations.
2
Mount power supply and remove
junction box cover. Carefully remove
knockout for AC line input wires.
Install appropriate electrical fittings
in the knockout holes for wire
protection.
Connect the AC line to the black
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
2
) twist-on
wire connectors. Ground power
supply by connecting green wire
with yellow stripe to grounding
screw. Replace junction box cover.
1
White
(neutral)
Black (line)
Green with
yellow stripe
(ground)
AC line
3
To Tetra LED System
Output wires
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE:
• Use only Tetra
®
supply wire to make connection from Tetra
®
power
supply to Tetra
®
LED strip.
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm
2
)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation
électrique Tetra
®
.
RISQUES D’INCENDIE
• N’utilisez que le fil d’approvisionnement Tetra
®
pour faire la
connexion entre l’alimentation Tetra
®
et la bande DEL Tetra
®
.
• N’utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82 mm
2
).
• Respectez tous les codes locaux.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
Power Supply Installation