background image

imagination at work

Power Supply Features

(GEPS12-180U)

• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX,  

 

  Tetra PowerStrip and Tetra miniStrip lighting systems

• Class 2 wiring per NEC Article 725 (SELV equivalent)

• Damp location rated

• IP66 rated: separate enclosure required

• Three 60 watt output banks

Tetra

®

 

LED Systems Power Supply

GE

Lighting Solutions

Installation Guide

12

Volt

Connect the supply wire that is 

attached to the Tetra LED System to 

the red (+) and black (-) output wires 

of the power supply as outlined in 

the “

Electrical Connections

” section 

of your LED system’s Installation 

Instructions.

NOTE:

 Three 60 watt output banks per 

power supply. Do not interconnect 

output terminations.

2

Mount power supply and remove 

junction box cover. Carefully remove 

knockout for AC line input wires. 

Install appropriate electrical fittings 

in the knockout holes for wire 

protection. 

Connect the AC line to the black 

(line) and white (neutral) input 

wires of the power supply using 

18-14 AWG (0.82-2.08 mm

2

) twist-on 

wire connectors. Ground power 

supply by connecting green wire 

with yellow stripe to grounding 

screw. Replace junction box cover. 

1

White 

(neutral)

Black (line)

Green with 

yellow stripe 

(ground)

AC line

3

To Tetra LED System

Output wires

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference

received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.

RISK OF ELECTRIC SHOCK:

• Disconnect power at fuse box or circuit breaker before servicing or  

  installing product.
• Properly ground Tetra

®

 power supply.

RISK OF FIRE:

• Use only Tetra

®

 supply wire to make connection from Tetra

®

 power  

  supply to Tetra

®

 LED strip.

• Use only approved wire for input/output connection. 

  Minimum size 18 AWG (0.82 mm

2

)

• Follow all local codes.

RISQUES DE DÉCHARGES ÉLECTRIQUES

• Coupez l’alimentation électrique à la boîte de fusibles ou au    

  disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation    

  électrique Tetra

®

.

RISQUES D’INCENDIE

• N’utilisez que le fil d’approvisionnement Tetra

®

 pour faire la    

  connexion entre l’alimentation Tetra

®

 et la bande DEL Tetra

®

.

• N’utilisez que des fils approuvés pour les entrées/sorties de    

  connexion. Taille minimum 18 AWG (0.82 mm

2

).

• Respectez tous les codes locaux.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

WARNING/AVERTISSEMENT

Power Supply Installation

Отзывы: