All commas are the international symbol for the decimal point.
•
Please remark, that the air temperature increase per slot will be
higher than 2.5 K when using airflows less than 50 CFM or 2.75 m/s
under high power consumption conditions.
Power Consumption
The following table is intended to help you calculate the power consumption
of an ASLP11 system. For measurement, the ASLP11 board is mounted on an
AMC carrier.
Table 14: ASLP11 typical Power consumption (+12.0 V)
CPU, DRAM, PCIe switch
Idle, CPU
cores at
90 °C
one core running
TDP at 100 °C
both cores running
TDP at 100 °C
1.5 GHz, 512 MB, no PCIe
switch
32 W
39 W
45 W
1.5 GHz, 2 GB, PCIe switch 35 W
45 W
51 W
2.16 GHz, 2 GB, PCIe
switch
35 W
60 W
75 W
•
When the operating system brought the board into power down state S5,
the CPU supply is switched off and the total power consumption is
around 8W
•
The idle power consumption values are shown using an operating system
which can handle the CPU speed step feature via ACPI
•
The onboard IPMI controller consumes less than 0.1 A from the 3.3 V
management power supply.
•
Connectors P1680 provide VCC voltage (+5 V). The total current drawn
from this source must not exceed 0.5 A.
GE Intelligent Platforms – ASLP11 Hardware Reference Manual, Third Edition
Page 54
Содержание TELUM ASLP11
Страница 10: ......
Страница 19: ...Figure 2 Block diagram GE Intelligent Platforms ASLP11 Hardware Reference Manual Third Edition Page 19...
Страница 22: ......
Страница 26: ......
Страница 30: ......
Страница 52: ...GE Intelligent Platforms ASLP11 Hardware Reference Manual Third Edition Page 52...
Страница 60: ......
Страница 63: ...GE Intelligent Platforms ASLP11 Hardware Reference Manual Third Edition Page 63...