GE Multilin
T35 Transformer Protection System
B-43
APPENDIX B
B.4 MEMORY MAPPING
B
AB03
Operand for IEC 61850 XCBR2.ST.Loc Status
0 to 4294967295
---
1
F300
0
AB05
Command to Clear XCBR2 OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
AB06
Operand for IEC 61850 XCBR3.ST.Loc Status
0 to 65535
---
1
F300
0
AB08
Command to Clear XCBR3 OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
AB09
Operand for IEC 61850 XCBR4.ST.Loc Status
0 to 65535
---
1
F300
0
AB0B
Command to Clear XCBR4 OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
AB0C
Operand for IEC 61850 XCBR5.ST.Loc Status
0 to 65535
---
1
F300
0
AB0E
Command to Clear XCBR5 OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
AB0F
Operand for IEC 61850 XCBR6.ST.Loc Status
0 to 65535
---
1
F300
0
AB11
Command to Clear XCBR6 OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
IEC 61850 LN Name Prefixes (Read/Write Settings)
AB30
IEC 61850 Logical Node LPHD1 Name Prefix
0 to 65534
---
1
F206
(none)
AB33
IEC 61850 Logical Node PIOCx Name Prefix (72 items)
0 to 65534
---
1
F206
(none)
AC0B
IEC 61850 Logical Node PTOCx Name Prefix (24 items)
0 to 65534
---
1
F206
(none)
AC53
IEC 61850 Logical Node PTUVx Name Prefix (13 items)
0 to 65534
---
1
F206
(none)
AC7A
IEC 61850 Logical Node PTOVx Name Prefix (10 items)
0 to 65534
---
1
F206
(none)
AC98
IEC 61850 Logical Node PDISx Name Prefix (10 items)
0 to 65534
---
1
F206
(none)
ACB6
IEC 61850 Logical Node RBRFx Name Prefix (24 items)
0 to 65534
---
1
F206
(none)
ACFE
IEC 61850 Logical Node RPSBx Name Prefix
0 to 65534
---
1
F206
(none)
AD01
IEC 61850 Logical Node RRECx Name Prefix (6 items)
0 to 65534
---
1
F206
(none)
AD13
IEC 61850 Logical Node MMXUx Name Prefix (6 items)
0 to 65534
---
1
F206
(none)
AD25
IEC 61850 Logical Node GGIOx Name Prefix (5 items)
0 to 65534
---
1
F206
(none)
AD34
IEC 61850 Logical Node RFLOx Name Prefix (5 items)
0 to 65534
---
1
F206
(none)
AD43
IEC 61850 Logical Node XCBRx Name Prefix (6 items)
0 to 65534
---
1
F206
(none)
AD55
IEC 61850 Logical Node PTRCx Name Prefix (6 items)
0 to 65534
---
1
F206
(none)
AD67
IEC 61850 Logical Node PDIFx Name Prefix (4 items)
0 to 65534
---
1
F206
(none)
AD73
IEC 61850 Logical Node MMXNx Name Prefix (37 items)
0 to 65534
---
1
F206
(none)
ADE2
IEC 61850 Logical Node CSWIx Name Prefix (30 items)
0 to 65534
---
1
F206
(none)
AE3C
IEC 61850 Logical Node XSWIx Name Prefix (24 items)
0 to 65534
---
1
F206
(none)
IEC 61850 GGIO4 General Analog Configuration Settings (Read/Write Setting)
AF00
Number of Analog Input Points in GGIO4
4 to 32
---
4
F001
4
IEC 61850 GGIO4 Analog Input Points Configuration Settings (Read/Write Setting) (32 modules)
AF10
IEC 61850 GGIO4 Analog Input 1 Value
---
---
---
F600
0
AF11
IEC 61850 GGIO4 Analog Input 1 Deadband
0.001 to 100
%
0.001
F003
100000
AF13
IEC 61850 GGIO4 Analog Input 1 Minimum
–1000000000000 to
1000000000000
---
0.001
F060
0
AF15
IEC 61850 GGIO4 Analog Input 1 Maximum
–1000000000000 to
1000000000000
---
0.001
F060
1000000
AF17
...Repeated for IEC 61850 GGIO4 Analog Input 2
AF1E
...Repeated for IEC 61850 GGIO4 Analog Input 3
AF25
...Repeated for IEC 61850 GGIO4 Analog Input 4
AF2C
...Repeated for IEC 61850 GGIO4 Analog Input 5
AF33
...Repeated for IEC 61850 GGIO4 Analog Input 6
AF3A
...Repeated for IEC 61850 GGIO4 Analog Input 7
AF41
...Repeated for IEC 61850 GGIO4 Analog Input 8
AF48
...Repeated for IEC 61850 GGIO4 Analog Input 9
AF4F
...Repeated for IEC 61850 GGIO4 Analog Input 10
AF56
...Repeated for IEC 61850 GGIO4 Analog Input 11
AF5D
...Repeated for IEC 61850 GGIO4 Analog Input 12
AF64
...Repeated for IEC 61850 GGIO4 Analog Input 13
AF6B
...Repeated for IEC 61850 GGIO4 Analog Input 14
AF72
...Repeated for IEC 61850 GGIO4 Analog Input 15
AF79
...Repeated for IEC 61850 GGIO4 Analog Input 16
AF80
...Repeated for IEC 61850 GGIO4 Analog Input 17
AF87
...Repeated for IEC 61850 GGIO4 Analog Input 18
Table B–10: MODBUS MEMORY MAP (Sheet 35 of 52)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание T35 UR Series
Страница 10: ...x T35 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Страница 48: ...2 18 T35 Transformer Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 314: ...5 192 T35 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 338: ...6 24 T35 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 350: ...7 12 T35 Transformer Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 366: ...8 16 T35 Transformer Protection System GE Multilin 8 2 CYBERSENTRY 8 SECURITY 8 ...
Страница 382: ...9 16 T35 Transformer Protection System GE Multilin 9 5 COMMISSIONING TEST TABLES 9 COMMISSIONING 9 ...
Страница 406: ...A 14 T35 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 540: ...D 10 T35 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Страница 552: ...E 12 T35 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 560: ...F 8 T35 Transformer Protection System GE Multilin F 3 WARRANTY APPENDIX F F ...