Troubleshooting
98
T2100-ST1 Treadmill, 110V / T2100-ST2 Treadmill, 220V
2097937-002 Rev G
11 March 2019
Drive PC2303-012-N status LED CODE list
When the drive is faulted, the Status LED blinks out the fault code.
The Status LED blinks the proper number of times, pauses with the
Status LED off, and then repeats the blink code.
Status Code
Description
Fault Retention
No Blink
No faults, power stage enabled
-
Fast Blink
No faults, power stage disabled
-
LED Off
Ac line power insufficient
-
1 Blink
PWM_CMD Stuck Low
Latched (See
Note 1
)
2 Blink
Gcoder Feedback Error
Latched (See
Note
1
)
3 Blink
Not Used
-
4 Blink
Output Over Current
Latched (See
Note 1
)
5 Blink
Control Supply Under Voltage
Self-Resetting
6 Blink
Drive Over Temperature
Latched (See
Note 1
)
7 Blink
Bus Over Voltage
Self-Resetting
8 Blink
Output Short Circuit
Latched (See
Note 1
)
Note 1
: Contact local GE customer support representative for possible Drive
PC2303-012-N replacement.
Running Belt High Speed Application
When operation the treadmill at a High-Speed Application. The
running belt is displaying hesitation/slippage of the running belt
with each foot plant. The following may be detected:
•
Inspect the backing of the running belt for a fabric
breakdown, replace the running belt and flip running
deck.
•
If grooves are found on the running deck. Inspect the
running belt fabric. If running belt backing exhibits
abnormal wear replace running and flip running deck.
NOTE:
The running deck is reversible providing a new running
surface. If both sides of the running deck have been used
replace running deck.
System Flash Log Retrieval
When retrieving on UPS (Software Version 1.1812 and later
FGLF0495-03 Smart Power Supply system flash log file power the